29

Correct

Incorrect

There are hundreds of sealant details but all of

them should address the same principle:

avoid

three-sided adhesion.

Three-sided adhesion is the cause of the majority

of transition joint failures in rehabilitation

projects.

Joint

Bondbreaker

Joint

No Bondbreaker

MOVEMENT

MOVEMENT

Proper joint treatment

with bondbreaker tape

installed. The fact that the

sealant rides on the top of

the bondbreaker (no three-

sided adhesion) allows the

sealant to work properly

without a cohesive tear.

This is an exaggerated

illustration of the same

joint where the sealant

has been installed over

the masonry without a

bondbreaker. The result

is a cohesive tear when

the joint moves.