Risk Reduction and Functional Safety Standards
§
Current best practice for instrumented safety in the process sector is
IEC61511, BS EN 61511 in the UK
§
This is a Functional Safety Standard
§
It is a risk based approach
§
It uses a Safety Lifecycle to organise the activities
§
It introduces Safety Integrity Levels (SIL) as a measure of the amount of
risk reduction
§
SIL 1 is lowest level of risk reduction, SIL 4 the highest
§
61511 has technical and managerial requirements
The SIL 2 Safety Instrumented Function
§
Company owns and operates a number of petroleum storage terminals
§
Top Tier COMAH site
§
Offload into storage tanks from ship
§
Loaded into road tankers