AOAC EXPERT REVIEW PANEL FOR MICROBIOLOGY FOR FOODS AND ENVIRONMENTAL SURFACES
AOAC Expert Review Panel Final Action Feedback
AOAC OFFICIAL METHOD 2013.11
VIDAS®
LISTERIA MONOCYTOGENES
XPRESS (LMX) METHOD, AOAC OFFICIAL METHOD 2013.11,
LISTERIA MONOCYTOGENES
IN A VARIETY OF FOODS
MANUSCRIPT INFORMATION
VIDAS®
Listeria monocytogenes
Xpress (LMX) Method, AOAC Official Method 2013.11,
Listeria
monocytogenes
in a Variety of Foods
o Manuscript publication reference, if available.
Reference:
J. AOAC Int. 97, 442(2014)
o OMA methods have manuscripts unless otherwise noted in the OMA. Author(s) name(s), Journal
Name, Volume number, Issue number (if applicable), Page numbers (if applicable).
Reference:
J. AOAC Int. 97, 442(2014)
Evaluation of VIDAS®
Listeria monocytogenes
Xpress (LMX) for the Detection of
Listeria monocytogenes
in a Variety of Foods: Collaborative Study
Erin Crowley, Patrick Bird, Jonathan Flannery, M. Joseph Benzinger, Jr, Kiel Fisher, Megan Boyle,
Travis Huffman, Ben Bastin, Paige Bedinghaus, Will Judd, Thao Hoang, James Agin, and David Goins
Q Laboratories, Inc., 1400 Harrison Ave, Cincinnati, OH 45214
Ronald L. Johnson
1
bioMérieux, Inc., 595 Anglum Rd, Hazelwood, MO 63042
Collaborators: J. Adams; A. Bollenbacher; B. Brahmanda; R. Burkhart; J. Cannon; A. Capps; L. Cesanas-
Tyson; D. Davis; D. Ebbing; H. Elgaali; B. Hand; R. Hiles; J. Hirsch; B. Howard; J. Jolly; S. Joseph; A. Kehres;
K. Klemms; J. Li; B. May; M. Michels; J. Mills; S. Moore; N. Nagassar; S. Owusu; N. Palen; L. Parker; B.
Paul; B. Perry; J. Pickett; N. Rogman; G. Rosario; P. Rule; C. Said; M. Sala-Rhatigan; A. Stegmann; T.
Stubblefield; K. Wiggins; J. Zimmerman
METHOD APPLICABILITY
o In your experience using the method, does the method perform according to the method's
applicability as written? yes
o Does the applicability of the method need to be improved, such as potential method scope expansions
or are there potential points of concern? no
SAFETY CONCERNS
o In your experience with the method, are there any safety concerns that were identified while using or
regarding use of the method?
no
Page
1