Background Image
Table of Contents Table of Contents
Previous Page  911 / 1195 Next Page
Information
Show Menu
Previous Page 911 / 1195 Next Page
Page Background

More General ART Strategies

Patient-specific PTV

Constructed with repeated

imaging.

Based on the first few days of

treatment.

Adapt the plan once using

MLC beam apertures to

correct margins and

systematic error.

No on-line interventions.

Reconstruct & Adapt Dose

Imaging feedback to assess dose in

moving and deforming organs.

4D

patient models.

Relate target/organ segmentations

Track deforming organs

Accumulate fraction doses

Evaluate dose delivered: to date,

current fraction, anticipated

trajectory

.

Yan et al PMB 42 (1997) 123–132

D.Yan, D. Lockman et al, IJROBP 48, 289–302, 2000

Martinez, Yan et al IJROBP 50, 1226–1234, 2001

D. Brabbins et al, IJROBP 61. 400–408, 2005

Nuver et al IJROBP 67(5); 1559-67 (2007)

Hugo et al Radioth & Oncol 78 (2006) 326–331

J Löf et al, PMB 43 (1998) 1605–1628

Birkner M et al, Med Phys. 2003 30(10):2822-31

Rehbinder et al, Med Phys. 2004 31(12):3363-71