5)
ITV
FOR INTACT CARCINOMA OF THE CERVIX
Buchali 1999, Huh
2004
INTERNAL MOBILITY OF TARGETS AND OAR
•
2 MR images, pre- and during EBRT
•
Mobility of uterine corpus upwards 3-15 mm, cervix 1-6 mm
•
Changes in cervico-uterine angle 0.1-67.8
°
•
•
Weak relation between bladder filling and organ dose
•
No relation between rectum filling and organ dose