STEC Workflow Collaborative Study Protocol

May 2016

DRAFT

2

3.4

Collaborators will each receive1test portion set as described in Table 2. All test portions

within a set will be randomized and blind coded so that the collaborators do not know

which test portions are from which contamination level. The randomization will be

different for each collaborator. In addition, collaborators will receive 1 portion of

ground beef for aerobic plate count.

Table 2. Test portion set for each collaborator

Matrix

Test Portion

Size

Number of

Test Portions

Number per

Level

Method(s)

Ground

beef

325

36

12 uninoc.

12 low

12 high

mericon

and MLG

5.09 (Paired)

3.5

Study schedule

3.5.1

All media and reagents as outlined in Appendix 8.2 will be prepared by QLabs

and shipped to collaborator sites to arrive no later than the Wednesday before

shipment of test portions.

3.5.2

Test kits and Study Materials as outlined in Appendix 8.2 will be shipped to

collaborators by QIAGEN to arrive no later than the Wednesday before

shipment of test portions.

3.5.3

Test portions will be shipped refrigerated by overnight courier to each test site

to arrive on a Friday. The specific date will be determined once collaborators

and sites are confirmed.

3.5.4

All collaborators will begin analyses on the following Monday. Only the

coordinating laboratory will conduct MPN analyses.

3.5.5

Data forms will be completed and emailed to the co-Study Director within 2

weeks of initiation of analyses.

Table 3. Study Schedule (Specific Dates TBD)

Collaborator

Activity

Receipt of

Media and

Reagents

Receipt of Test

Kits and

Materials

Receipt of Test

Portions Set

Initiation of

Analyses

Submission of

Data Report

Form

Date

Week 1,

Wednesday

Week 1,

Wednesday

Week 1,

Friday

Week 2,

Monday

Week 4,

Monday

4.0

Test Portion Preparation and Analysis

4.1

Test Portion Preparation

4.1.1

The Coordinating Laboratory, Q Laboratories, will screen fresh raw ground beef

for natural STEC contamination using the

mericon

E. coli O157 Screen Plus and

OMAMAN-36 B : Collaborative Study Protocol

For ERP Use Only

January 2017

AOAC Research Institute