Background Image
Previous Page  19 / 24 Next Page
Information
Show Menu
Previous Page 19 / 24 Next Page
Page Background

P817-1176

19

Photo M

Manual

operating

handle

8—Operation

Manual Operation

Step 1. — Manual Switch Operation

• Decouple the motor as outlined in the

Decoupling & Coupling Motor Operator

section

• Refer to Figure 10

NOTE: Removing the manual operating

handle from the enclosure activates a

safety device that makes the motor opera-

tor inoperable until the drive mechanism

has been decoupled, or the manual operat-

ing handle is returned to its storage posi-

tion. Do not attempt to defeat this safety

device.

• Remove the manual operating handle from

its cradle in the bottom of the enclosure

(see Photograph M)

• Attach the manual operating handle to the

overhead switch control pipe by using the

bent arm pin and cotter pin as shown in

Figure 10

• Manually operate the overhead switch as

directed by the switch manufacturer

Hazardous voltages and high speed moving parts.

These can cause death, serious personal injury or damage equip-

ment.

Lock out power at circuit breaker/fuse box and turn control box main

power switch “OFF” before attempting to manually operate this unit.

Manual operating handle removed from enclosure and at-

tached to switch control pipe with bent arm pin and cotter

pin

Figure 10 – Manual Operating Handle

!

WARNING