P817-1176
19
Photo M
Manual
operating
handle
8—Operation
Manual Operation
Step 1. — Manual Switch Operation
• Decouple the motor as outlined in the
Decoupling & Coupling Motor Operator
section
• Refer to Figure 10
NOTE: Removing the manual operating
handle from the enclosure activates a
safety device that makes the motor opera-
tor inoperable until the drive mechanism
has been decoupled, or the manual operat-
ing handle is returned to its storage posi-
tion. Do not attempt to defeat this safety
device.
• Remove the manual operating handle from
its cradle in the bottom of the enclosure
(see Photograph M)
• Attach the manual operating handle to the
overhead switch control pipe by using the
bent arm pin and cotter pin as shown in
Figure 10
• Manually operate the overhead switch as
directed by the switch manufacturer
Hazardous voltages and high speed moving parts.
These can cause death, serious personal injury or damage equip-
ment.
Lock out power at circuit breaker/fuse box and turn control box main
power switch “OFF” before attempting to manually operate this unit.
Manual operating handle removed from enclosure and at-
tached to switch control pipe with bent arm pin and cotter
pin
Figure 10 – Manual Operating Handle
!
WARNING