Page Background

Edition 47 5-89

5

519/569 Features:

Heavy-duty boom options

range in length from 8.2 m

(27 ft) to 10.90 m (36 ft) for handling a variety of tree

lengths.

Weatherproof electric service panels

include starters,

controls, transformers, circuit breakers and fuse blocks.

Electric motors

are rated for severe duty.

Resilient Pad Mounting System

includes a set of

special rubber isolators on each mounting fastener

that absorbs stress in two directions.

Hydraulic pilot joystick controls and rocker swing pedal

are ergonomically designed for ease of operation and

maximum loader control.

Millyards

Stationary Mount

Knuckleboom Loaders

Features

Specifications

MODEL

519 SM 519 SM/EHC

569 SM 569 SM/EHC

Electric Power Supply (standard)

460Volt: 60 Hz

460Volt: 60 Hz

460Volt: 60 Hz

460Volt: 60 Hz

Electric Power Supply (optional)*

575Volt: 60 Hz

575Volt: 60 Hz

575Volt: 60 Hz

575Volt: 60 Hz

Electric Motor @ 1800 RPM 56 kW

75 hp

56 kW

75 hp

74 kW

100 hp

74 kW

100 hp

OperatingWeight

7218.9 kg

15,915 lb

6946.7 kg

15,315 lb

8593.3 kg

18,945 lb

8321.1 kg

18,345 lb

Hydraulic System:

System Pressure

15 168 kPa

2200 psi

15 168 kPa

2200 psi

17 237 kPa

2500 psi

17 237 kPa

2500 psi

Swing Pressure

16 547 kPa

2400 psi

16 547 kPa

2400 psi

17 237 kPa

2500 psi

17 237 kPa

2500 psi

Swing Speed

8 RPM

8 RPM

7 RPM

7 RPM

Knuckleboom Length (standard)

8.2 m

27'0"

8.2 m

27'0"

9.9 m

32'6"

9.9 m

32'6"

Knuckleboom Length (optional)

9.1 m

30'0"

9.1 m

30'0"

11.0 m

36'0"

11.0 m

36'0"

*

NOTE:

Other Electric Power options available by special quote.

Electrical Code Requirements:

Cat Electric Stationary Mount Loaders are designed to

meet National Electrical Code (NEC) requirements in

the United States. However, the Dealer/Customer is

responsible to investigate local Electrical Code require-

ments that may exist and make updates as required to

the machine to meet additional local requirements.

Incoming Supply Power Requirements

for the Stationary Mount Loaders:

Incoming supply power specification for all stationary

mount loaders must be within ± 5% of nominal for proper

operation/reliability of the machine. A customer/dealer

supplied transformer must be installed to accommo-

date the incoming power requirements if needed.