ESTRO IMRT course 2015

Dose Calculation in Static and Rotational IMRT

Brussels October 8th, 2015

-58-

Dose calculation issues ‚in practice‘:

Dose calculation in presence of CT artifacts

•

typical cases in RT: dental

metal implants, hip implants

•

significant dose calculation

errors possible in soft tissue

artifact regions due to wrong

Hounsfield (CT-) values

•

Hounsfield values of metal

structures itself wrong as well

AND usually dose calculation

algorithms do not model

radiation transport through

metal correctly

→

do not trust your dose ‘behind’

metal structures!

→

if possible (hip implants), try

to avoid beam directions passing

metal structures

further reading e.g. Kim et al. 2006 (Radiother. Oncol. 79(2))

pragmatic approach in

our department:

dummy contours,

density override with

water density