5/82

Hand Tools

5

Design:

Casing made of impact-resistant plastic. With selectable limit values for ISO

measurement, green LED for test passed, red LED for test/external voltage, switchable probe

tip for triggering the measuring process, internal memory, voltage measurement with low-

pass filter, automatic discharge of capacitive voltage. Insulation resistance (50 V-1000 V)

with calculation of the resulting current leak, polarisation index (PI) and dielectric absorption

ratio (DAR).

Application:

For insulation and low ohmic measurements on electrical systems, devices,

wires, engines and generators.

Scope of delivery:

Measuring device, switchable probes, measurement lines, crocodile

clamps, rubber case, batteries and bag.

Order No.

0100

Model

IT 101

5586

462.50

Low resistance

0.01 Ohm–40 Ohm

Insulation resistance

1 kOhm–20 GOhm

Resistance

0.01 Ohm–40 kOhm

Voltage

0.1 V–600 V

Measurement value memory

500

Measuring procedure

TRUE RMS

Measurement category

CAT IV 600 V

Dimensions (L x W x H)/weight

207 x 95 x 52 mm/630 g

Batteries

4 x Mignon AA/LR6

(W514)

Insulation and resistance measuring instrument IT 101

IP 40

CAT

IV

Design:

Automatic test procedure with pass/fail indication for Class

I, II (III) and line test. Voltage measurement at external isolated safety

plugs. Three-phase test items tested via optional measuring adapter.

The limit values are preset in line with VDE standard.

Battery

capacity for 2500 test samples. Supplied with carry bag and belt, test

lead with crocodile clip, power cable and batteries.

Application:

For

safety checks (DGUV-Rule-3-tests) of electrical

equipment and work materials according to VDE 0701-0702,

DGUV Rule 3, OVE/ÖNORM E 8701, NEN 3140. Suitable for electrical

engineering, industry, maintenance works, servicing and communities.

Order No.

0710

0725

Model

ST 710

ST 725

5561

456.50

735.00

Protective conductor resistance

0.05–20 Ohm

0.05–20 Ohm

Test current

± 200 mA DC

± 200 mA DC

Insulation resistance

0.1–20 MOhm

0.1–20 MOhm

Test voltage

500 V DC

250 V/500 V

Protective earth/contact cur-

rent via differential measure-

ment/direct measurement

0.25–20 mA/0.1–2 mA

Protective earth/contact

current via alternative cur-

rent leakage method

0.1–20 mA

0.25–20 mA

FI/RCD protective

conductor test current

30 mA + 150 mA

Performance test

R

PE

, R

ISO

, continuity and short

circuit test of the phase/neutral wire

R

PE

, R

ISO

, continuity and short

circuit test of the phase/neutral wire

Voltage

50–270 V

50–270 V

Dimensions (L x W x H)/weight

270 x 115 x 55 mm/800 g

270 x 115 x 55 mm/950 g

Batteries

6 x Mignon batteries 1.5 V

6 x Mignon AA/LR6

(W511)

ST 710/ST 725 device testers

5561 0710

5561 0725

5561

Battery operated.

Testing of electrical devices/tools

with on/off button, heating devices, power tools, lights,

cable reels, multiple distributors and domestic appliances.

Protective earth/contact current via alternative current

leakage method.

0710

5561

Battery and mains operation.

Testing of devices with

mains voltage-dependent switching elements/power

supply/relay, such as electronically controlled devices/

tools, information and communication technology devices

and equipment that can be fully tested only with mains

voltage.

Protective earth/contact current via differential

measurement/direct measurement.

Data memory

for 999 test objects, read out via micro-USB port. Also

includes integrated real-time clock to store the measured

values with test date, micro USB cable and reading

software (CD).

0725

600 V

Test and measuring devices