5/80
Hand Tools
5
Design:
Casing made of impact-resistant plastic with integrated rubber protection frame.
With
voltage sensor
and
TRUE RMS measuring process
for precise measurement results
also in non-sinus signal sequences. Supplied with compact protective case, dual-insulated
safety measurement lines and batteries.
Digital multimeter for industrial application
5587
MM 5-1
0152
m
5587
MM 5-2
Micro ampere measuring ranges (400 µA DC/4000 µA DC)
for the ionisation current measurement in heating systems.
0155
m
5587
MM 6-1
Automatic voltage function for automatic identification of DC/AC voltage,
low input impedance (LoZ) for the suppression of capacitive/inductive interspersed
voltages.
0210
m
5587
MM 6-2
Automatic voltage function for automatic identification of DC/AC voltage,
low input impedance (LoZ) for the suppression of capacitive/inductive interspersed
voltages.
0215
m
5587
MM 7-1
Automatic voltage function for automatic identification of DC/AC voltage,
low input impedance (LoZ) for the suppression of capacitive/inductive interspersed
voltages. Delivery includes wire temperature sensor with adapter.
0251
5587 0251
CAT
IV
600 V
5587 0215
CAT
IV
600 V
5587 0210
CAT
IV
600 V
5587 0155
CAT
III
600 V
5587 0152
CAT
III
600 V
IP 30
Order No.
0152
0155
0210
0215
0251
Model
MM 5-1
MM5-2
MM 6-1
MM 6-2
MM 7-1
5587
94.10
144.00
164.00
180.00
210.00
DC voltage
0.1 mV–600 V
0.1 mV–600 V
0.1 mV–1000 V
0.1 mV–1000 V
10 µV–1000 V
AC voltage
0.1 mV–600 V
0.1 mV–600 V
0.1 mV–1000 V
0.1 mV–1000 V
10 µV–1000 V
Direct current
–
1 mA–10 A
0.1 µA–600 µA
1 mA–10 A
10 µA–10 A
Alternating current
–
0.1 µA–10 A
0.1 µA–600 µA
1 mA–10 A
10 µA–10 A
Resistance
0.1 Ohm–40 MOhm 0.1 Ohm–40 MOhm 0.1 Ohm–40 MOhm 0.1 Ohm–40 MOhm 0.1 Ohm–40 MOhm
Continuity/diodes
yes/yes
yes/yes
yes/yes
yes/yes
yes/yes
Frequency
0.01 Hz–50 kHz
0.01 Hz–50 kHz
0.01 Hz–100 kHz
0.01 Hz–100 kHz
0.01 Hz–100 kHz
Capacity
0.01 nF–1 mF
0.01 nF–1 mF
1 nF–10 mF
1 nF–10 mF
1 nF–10 mF
Temperature
–
–40°C to +400°C –40°C to +400°C
–
–40°C to +400°C
Measurement category
CAT III 600 V
CAT III 600 V
CAT IV 600 V
CAT IV 600 V
CAT IV 600 V
Measuring procedure
TRUE RMS
TRUE RMS
TRUE RMS
TRUE RMS
TRUE RMS
Protection type
IP 30
IP 30
IP 30
IP 30
IP 30
Batteries
2 x micro AAA/LR03 2 x micro AAA/LR03 1 x 6LR61 block battery 1 x 6LR61 block
battery
1 x 6LR61 block battery
Display
LCD
LCD
LCD
LCD
LCD
(W514)
Test and measuring devices
954