Hand Tools
5
Digital current clamp multimeter
5585
0101
5585
0102
5585
0200
5585
0501
5585
0700
5585
0900
5585
1100
m
Order No.
0101
0102
0200
0501
0700
0900
1100
Model
CM 1-1
CM 1-2
CM 2
CM 5-1
CM 7
CM 9
CM 11
5585
62.00
82.80
177.50
257.00
276.00
408.50
329.00
DC voltage
–
0.1 V–600 V 0.1 mV–600 V 0.7 V–1000 V 0.1 V–1000 V
–
0.1 V–600 V
AC voltage
–
0.1 V–600 V 1 mV–600 V 1.3 V–750 V 0.1 V–750 V
–
0.01 V–600 V
Direct current
–
–
10 mA–300 A 0.9 A–600 A 0.1 A–1000 A
–
0.1 mA–10 A
Alternating current
10 mA–400 A 0.1 A–400 A 100 mA–300 A 0.9 A–600 A 0.1 A–1000 A 1 µA–100 A 0.1 mA–20 A
Resistance
–
0.1 Ohm–
20 MOhm
0.1 Ohm–
40 MOhm
1 Ohm–
10 kOhm
0.1 Ohm–
400 Ohm
–
0.1 Ohm–
600 kOhm
Continuity
–
yes
yes
yes
yes
–
yes
Frequency
–
–
–
–
1 Hz–400 Hz
–
–
Measurement value memory
HOLD, MAX
HOLD
HOLD, MAX HOLD, ZERO HOLD, MAX/MIN,
PEAK, ZERO
HOLD, PEAK
HOLD,
MAX/MIN, ZERO
Measuring procedure
RMS
RMS
TRUE RMS TRUE RMS TRUE RMS TRUE RMS TRUE RMS
Pliers opening
30 mm
30 mm
25 mm
35 mm
53 mm
40 mm
23 mm
Measurement category
CAT III 600 V CAT III 600 V CAT III 300 V CAT IV 600 V CAT IV 600 V CAT III 300 V CAT IV 300 V
Protection type
IP 30
IP 30
IP 30
IP 30
IP 30
IP 30
IP 30
Batteries
1 x 6LR61
block battery
2 x micro
AAA/LR03
2 x micro
AAA/LR03
1 x 6LR61
block battery
1 x 6LR61
block battery
2 x micro
AAA/LR03
2 x micro
AAA/LR03
Display
LCD
LCD
LCD
LCD
LCD
LCD
LCD
(W514)
Design:
Housing made of impact-resistant, unbreakable plastic, with automatic
shutdown function.
Application:
For the safe current measurement at insulated cables, without having
to remove or damage the insulation.
CM 1-1
Supplied with compact protective bag and battery.
CM 1-2
Supplied with compact protective case, dual-insulated safety measurement lines and batteries.
CM 2
Precise due to true RMS measurement procedure TRUE RMS. Tested and approved according to IEC/EN 61010-1 (DIN VDE 0411-1).
Ideal for measuring small currents. Supplied with compact protective bag, double insulated safety measurement cables and batteries.
CM 5-1
Automatic selection of correct measuring function, incorrect measurements as a result of choosing the wrong measuring
range prevented, quick reaction times due to 5 samples per second. The voltage measurement takes place with low input impedance
(LoZ) for the suppression of capacitive/inductive interspersed voltages. For continuity and diode testing. Supplied with compact
protective bag, double insulated safety measurement cables and battery.
CM 7
Ideal for current measurement up to 1000 A (alternate and direct current).
Supplied with compact protective bag, double insulated safety measurement cables and battery.
CM 9 (stray current pliers)
Precise due to true RMS measurement procedure TRUE RMS. Resolution of 1 µA in the 6 A measuring
range For locating current leakages and measuring leakage and residual currents in electrical installations (VDE 0100) and devices
(VDE 0701/0702, DGUV Rule 3, Industrial Safety Ordinance). Measurement during normal operation of the plant/unit, ideal for
preventive maintenance and troubleshooting, reliable and easy to locate insulation faults. Connectible low-pass filter (50–60 Hz).
Supplied with compact protective bag and batteries.
CM 11
Ideal for fault detection in electrical systems, controls, devices and MV electrics. Precise measuring of small direct/alternate
currents with resolution of 0.1 mA. True real measuring value process TRUE RMS, measuring of standby, stray, difference, leakage
and load currents. Supplied with compact protective bag, double insulated safety measurement cables and battery.
IP 30
CAT
III
600 V
5585 0101
CAT
III
600 V
5585 0102
CAT
III
300 V
5585 0200
CAT
IV
600 V
5585 0501
CAT
IV
600 V
5585 0700
CAT
III
300 V
5585 0900
CAT
IV
300 V
5585 1100
Test and measuring devices