Table of Contents Table of Contents
Previous Page  955 / 1618 Next Page
Information
Show Menu
Previous Page 955 / 1618 Next Page
Page Background

5/81

Articles marked ◊ are not held in stock, procurement is effected at short notice.

Hand Tools

5

Digital current clamp multimeter

5585

0101

5585

0102

5585

0200

5585

0501

5585

0700

5585

0900

5585

1100

m

Order No.

0101

0102

0200

0501

0700

0900

1100

Model

CM 1-1

CM 1-2

CM 2

CM 5-1

CM 7

CM 9

CM 11

5585

62.00

82.80

177.50

257.00

276.00

408.50

329.00

DC voltage

0.1 V–600 V 0.1 mV–600 V 0.7 V–1000 V 0.1 V–1000 V

0.1 V–600 V

AC voltage

0.1 V–600 V 1 mV–600 V 1.3 V–750 V 0.1 V–750 V

0.01 V–600 V

Direct current

10 mA–300 A 0.9 A–600 A 0.1 A–1000 A

0.1 mA–10 A

Alternating current

10 mA–400 A 0.1 A–400 A 100 mA–300 A 0.9 A–600 A 0.1 A–1000 A 1 µA–100 A 0.1 mA–20 A

Resistance

0.1 Ohm–

20 MOhm

0.1 Ohm–

40 MOhm

1 Ohm–

10 kOhm

0.1 Ohm–

400 Ohm

0.1 Ohm–

600 kOhm

Continuity

yes

yes

yes

yes

yes

Frequency

1 Hz–400 Hz

Measurement value memory

HOLD, MAX

HOLD

HOLD, MAX HOLD, ZERO HOLD, MAX/MIN,

PEAK, ZERO

HOLD, PEAK

HOLD,

MAX/MIN, ZERO

Measuring procedure

RMS

RMS

TRUE RMS TRUE RMS TRUE RMS TRUE RMS TRUE RMS

Pliers opening

30 mm

30 mm

25 mm

35 mm

53 mm

40 mm

23 mm

Measurement category

CAT III 600 V CAT III 600 V CAT III 300 V CAT IV 600 V CAT IV 600 V CAT III 300 V CAT IV 300 V

Protection type

IP 30

IP 30

IP 30

IP 30

IP 30

IP 30

IP 30

Batteries

1 x 6LR61

block battery

2 x micro

AAA/LR03

2 x micro

AAA/LR03

1 x 6LR61

block battery

1 x 6LR61

block battery

2 x micro

AAA/LR03

2 x micro

AAA/LR03

Display

LCD

LCD

LCD

LCD

LCD

LCD

LCD

(W514)

Design:

Housing made of impact-resistant, unbreakable plastic, with automatic

shutdown function.

Application:

For the safe current measurement at insulated cables, without having

to remove or damage the insulation.

CM 1-1

Supplied with compact protective bag and battery.

CM 1-2

Supplied with compact protective case, dual-insulated safety measurement lines and batteries.

CM 2

Precise due to true RMS measurement procedure TRUE RMS. Tested and approved according to IEC/EN 61010-1 (DIN VDE 0411-1).

Ideal for measuring small currents. Supplied with compact protective bag, double insulated safety measurement cables and batteries.

CM 5-1

Automatic selection of correct measuring function, incorrect measurements as a result of choosing the wrong measuring

range prevented, quick reaction times due to 5 samples per second. The voltage measurement takes place with low input impedance

(LoZ) for the suppression of capacitive/inductive interspersed voltages. For continuity and diode testing. Supplied with compact

protective bag, double insulated safety measurement cables and battery.

CM 7

Ideal for current measurement up to 1000 A (alternate and direct current).

Supplied with compact protective bag, double insulated safety measurement cables and battery.

CM 9 (stray current pliers)

Precise due to true RMS measurement procedure TRUE RMS. Resolution of 1 µA in the 6 A measuring

range For locating current leakages and measuring leakage and residual currents in electrical installations (VDE 0100) and devices

(VDE 0701/0702, DGUV Rule 3, Industrial Safety Ordinance). Measurement during normal operation of the plant/unit, ideal for

preventive maintenance and troubleshooting, reliable and easy to locate insulation faults. Connectible low-pass filter (50–60 Hz).

Supplied with compact protective bag and batteries.

CM 11

Ideal for fault detection in electrical systems, controls, devices and MV electrics. Precise measuring of small direct/alternate

currents with resolution of 0.1 mA. True real measuring value process TRUE RMS, measuring of standby, stray, difference, leakage

and load currents. Supplied with compact protective bag, double insulated safety measurement cables and battery.

IP 30

CAT

III

600 V

5585 0101

CAT

III

600 V

5585 0102

CAT

III

300 V

5585 0200

CAT

IV

600 V

5585 0501

CAT

IV

600 V

5585 0700

CAT

III

300 V

5585 0900

CAT

IV

300 V

5585 1100

Test and measuring devices

955