Protection and control for three
phase LV motors
The modular MA electronic motor protection relay from
NewElec
, controls, monitors and protects the performance
of 3-phase LV motors.The relay measures electrical motor
variables such as current, phase unbalances, phase loss,
earth leakage, earth fault, short circuit and voltage condi-
tions. It can be used as either a standalone electronic motor
protection relay or as
part of an automated
process communi-
cating to a PLC. De-
signed for advanced
motor protection, the
MA comes complete
with integrated cur-
rent transformers and
earth leakage core in the range from 0,5 to 250A.The current
range can be extended using interposing CTs. Individual
fault status indication is provided by LEDs for easy diag-
nostics. It also stores the last four faults with time and date
stamping. The relay has five digital inputs and four output
contacts (two are programmable).The inputs will accommo-
date voltages from 24 to 220 Vac or dc, and for this reason,
it is an ideal choice for rapidly automating older plants
utilising the customer’s existing switchgear and optimising
the electrician’s circuit knowledge.
Enquiries: Email
sales@newelec.co.zaSoft starter for electric motors
TELE
has introduced a new 3PH soft starter with true 3 ph
control and integrated current control for a nominal motor
power 2,2 kW up to 22 kW. The unit is thyristor based and
integrates current measurement and current limiting without
external components and wiring.This function controls and
limits exactly the maximum motor current that is used to
start the whole system without overloading the motor and
drive mechanics. Additional power peaks and flickers in the
mains are reduced to a minimum, so the stability of the sup-
ply is much higher compared to star/delta or direct motor
starters. The overall size of the new MS3 is very compact
and saves space in the cabinet.The fan-less design improves
time between maintenance.
Asynchronous motors are the most common drive type
in machinery, automation, HVAC, pumps and transport busi-
ness. Direct starting these types of motors causes a high
inrush current, mechanical stress and destabilisation of the
mains. Using soft starters to
start the motor, eliminates or
at least minimises those dis-
advantages and guarantees a
long lasting and low mainte-
nance operation system.