Table of Contents Table of Contents
Previous Page  1057 / 1674 Next Page
Information
Show Menu
Previous Page 1057 / 1674 Next Page
Page Background

Results

3D-CRT Step and

shoot

Sliding

window

RapidArc

PTV

EVAL

V95% 99.7

99.7

99.7

99.6

PTV

EVAL

COIN 0.62

0.85

0.85

0.86

Ipsilat. breast

V50% 44.1

36.3

35.6

29.4

Ipsilat. lung

V10% 10.1

34.3

34.3

35.3

Heart (left)

V5% 1.5

22.6

20.9

48.3

Contralat. breast V5% 0

8.1

8.3

3.1

Contralat. lung V5% 0

8.4

8.3

6.3

-

good target volume

coverage can be achieved with all four techniques

-

conformality

is better with the

IMRT

techniques

-

ipsilateral breast can be better protected with IMRT

techniques (the best is the RapidArc)

-

contralateral breast and lung receive higher dose with IMRT

techniques than with 3D-CRT