Table of Contents Table of Contents
Previous Page  65 / 258 Next Page
Information
Show Menu
Previous Page 65 / 258 Next Page
Page Background

B

runt

et al

.:

J

ournal of

aoaC I

nternatIonal

V

ol

.

100, n

o

.

3, 2017

11

CCC used the sample Infant Formula Powder, Partially

Hydrolyzed Milk-Based, Lot No. 410057652Z (Table

2016.14A

, sample No. 7) for the determination of the LOD

and LOQ by spiking it with a low level of fructan (Orafti

P95, 0.046 g/100 g) and analyzing the sample 10 times on

2 different days.

The LOD and LOQ were then calculated as

= ×

LOD 3 SD

= ×

LOQ 10 SD

The LOD and LOQ results are summarized in Table 1 and

also meet the requirements outlined in the SMPRs (5). The

established values of the LOD and LOQ of both NRC and CCC

are in good agreement and meet the SMPRs (5).

Precision

It was known that only a few samples in the SPIFAN sample

kit contained fructan. To establish which samples contained

fructan, both NRC and CCC analyzed the whole series of 19

samples independently from each other. In both laboratories, six

of the 19 samples were found to contain fructans:

(1)

Sample No. 1, Child Formula Powder, Lot No. 00847RF00.

(

2

) Sample No. 9, Toddler Formula Powder, Milk-Based,

Lot No. 4052755861.

Figure 3. Calibration curves using chitobiose as internal standard (I.S.; left column) and plots of the relative residuals (right column).

(A) Fructose (Fru) at NRC; (B) glucose (Glc) at NRC; (C) fructose at CCC; and (D) glucose at CCC.

65