technology news

Quality control for data

cable production

The Centerview 8000 from Sikora is designed to deliver

non-contact continuous measurements of 8-point eccentricity,

4-axis diameter and 8-point ovality during the production of

data cables. The online repeatability and accuracy of these

non-contact measurements provide optimum control and

productivity on today’s production lines at all line speeds.

A feature of the Centerview is the automatic positioning of the

gauge head to the cable position. With this design, guide rollers

are not required to achieve precise single measuring values,

even at the micron level.

Centerview 8000 records the single measuring values with

highest precision. These are displayed at 4-points (diameter)

and 8-points (eccentricity, ovality) on the processor system

Ecocontrol 600, 1000 or 2000. Instantly, the operator has clear

information about eccentricity values that can be used for

control or crosshead adjustments.

Centerview 8000 is available as a stand-alone gauge head with

direct connection to a control system or a data collection system

for SPC (statistical process control). It can be combined with

the processor system, Ecocontrol, for constant accurate online

measurement and control.

The cloud diagram provides an additional way to present

the measuring values of the ongoing measurement at the

Ecocontrol. It provides information on distribution of short-term

variation of eccentricity in graphical form. Each dot corresponds

to one single measuring value of the eccentricity in relation to

the amount and angle. The extension of the cloud diagram is

the indicator for the standard deviation of the eccentricity.

The display of the single eccentricity values in the cloud diagram

shows the operator what eccentricity values remain and what

fluctuation the product has, even after a perfect centring.

This visualisation of the single values provides an option for

the operator to take appropriate measures to minimise the

eccentricity.