MRI-guided BT: GEC-ESTRO EQD2 spreadsheet
Treatment Reporting: PDR cervix
patient name
M. De Brabandere - July 2005
Prescr pulse dose d
f
in A [Gy
phys
]
tissue parameters T
1/2
[h] =
number of pulses N
[1/h] =
pulse interval [h]
∉Φ
[Gy] =
pulse time [h]
TARGET
Ext Beam Dose
Dose to A
Prescribed Dose in A
Target Vol (cc)
Dose to target Vol
D100
D90
Target coverage
V85
EQD2
[%]
V80
EQD2
[%]
V60
EQD2
[%]
V100 [%]
ORGANS AT RISK
∉Φ
[Gy] =
Ext Beam Dose
Bladder
cc
Bicru
D0.1cc
%
D1cc
%
D2cc
%
Rectum
cc
Ricru
D0.1cc
%
D1cc
%
D2cc
%
Sigmoid
cc
D0.1cc
%
D1cc
%
D2cc
%
dunne darm
cc
D0.1cc
%
D1cc
%
D2cc
%
#DEEL/0!
0,0
45,0
43,2
#DEEL/0!
0,0
45,0
43,2
H. M. 26-3-2008
GTV
BT
40,0
40,6
85,0
[Gy
phys
]
[Gy
EQD2
]
84,9
[Gy
phys
]
[Gy
EQD2
]
40,1
29,0
42,4
BT dose
Total dose (EBT + BT)
corresponding BT dose [Gy
phys
]
35,9
3
D
fract
[Gy
phys
]
0,0
45,0
43,2
#DEEL/0!
CTV IR
GTV
BT
CTV IR
CTVHR
GTV
BT
17,3
1,8
45,0
43,2
D
tot
[Gy
phys
]
D
tot
[Gy
EQD2
]
CTVHR
CTVHR
CTV IR
0,0
41,5
17,0
BT [Gy
EQD2
]
BT [Gy
phys
]
59,7
44,3
0,0
44,3
15,5
86,7
EBT + BT [Gy
EQD2
]
44,3
72,2
28,0
0,0
D
fract
[Gy
phys
]
D
tot
[Gy
phys
]
D
tot
[Gy
EQD2
]
1,8
45,0
44,3
BT dose
0,462
1,5
10
Total dose (EBT + BT)
40,000
78
1,0
0,2
[Gy
phys
]
[Gy
EQD2
]
[Gy
phys
]
[Gy
EQD2
]
0,0
45,0
43,2
43,5
46,8
88,5
90,0
0,0
45,0
43,2
33,0
31,7
78,0
74,9
28,5
26,0
73,5
69,2
0,0
0,0
45,0
43,2
45,0
43,2
0,0
45,0
43,2
0,0
45,0
43,2
0,0
45,0
43,2
0,0
45,0
43,2
Volume
48,4
0,2
2,1
4,1
0,2
4,2
46,3
47,3
2,2
4,3
0,2
2,1
LQ modeled
Tumor: a / b = 10 Gy
T ½ = 1,5 h
OAR: a / b = 3 Gy
T ½ = 1,5 h