7b. Radiation exposure

• Approx. 40% of the staff exposure in clinical PET/CT originates

from exposure during patient set-up (Seierstad et al, Radiat Prot

Dosimetry 2007)

• Complex positioning increases staff exposure

• Staff exposure should be reduced by

-

Patient instructions before tracer injection

-

Adaptation of positioning aids before injection

-

Trained RT staff should be involved during set up to shorten the

time needed for patient positioning

-

Use of motorized activity injectors

-

Use of new PET/CT technology that allows less activity to be

injected thanks to higher detector sensitivities

29 | D. Thorwarth | 09/2015