Table of Contents Table of Contents
Previous Page  344 / 1070 Next Page
Information
Show Menu
Previous Page 344 / 1070 Next Page
Page Background

Ma n Office: 405-631-9701

344

Fax: 405-631-0585

L

|

HVAC

COMMUNICATING SPLIT SYSTEM 18 SEER ENHANCED

AIR CONDITIONERS

4SCU18LS

208/230v Single Phase R410a Refrigerant

Dimensions

Locke# Model

A B C

L7788

4SCU18LS124P 37

s

35

s

44

L7789

4SCU18LS136P 37

s

35

s

44

L7790

4SCU18LS148P 37

s

35

s

44

L7791

4SCU18LS160P 37

s

35

s

44

Specifications

Locke# Model# Tonnage Voltage/ Hz/

Phase

Voltage

Range

Min.

Circuit

Ampacity

Max.

Overcurrent

Device

(amps)

Compressor

Fan Motor

Refrig.

Charge

(oz.)

Weight

(lbs.)

Rated

Load

(amps)

Locked

Rotor

(amps)

Rated

Load

(amps)

Rated

HP

Nom.

RPM

L7788

4SCU18LS124P

2

230/60/1 216-253 15.6

25

10.2 52

.7 1/3 825 302 297

L7789

4SCU18LS136P

3

230/60/1 216-253 23.7

40

16.6 82

.6 1/3 825 240 297

L7790

4SCU18LS148P

4

230/60/1 216-253 29.3

50

21.1 96

.8 1/3 825 252 297

L7791

4SCU18LS160P

5

230/60/1 216-253 34.4

60

25.6 118 .8 1/3 825 244 321

10 Year Limited Warranty on Compressor

5 Year Limited Warranty on all Parts (10 year available)

18 SEER AIR CONDITIONERS

COMPRESSOR

• High efficiency 2 stage Copeland

UltraTech™ scroll compressor

• R410a refrigerant

• Grommet mounted compressor for quiet

operation

• Internally protected against high

temperature motor overload conditions

• Heavy duty compressor sound blanket for

quiet operation

CABINET

• Full metal louvered jacket coil guard

protection

• Controls located in corner post for easy

installation and service

• Rounded corners for safety and attractive,

clean appearance

• Baked polyester paint finish over galvanized

steel for maximum durability

• PVC coated wire fan discharge grille

• External gauge ports for easy service

COIL

• Enhanced aluminum fins and copper tubing

for high efficiency and capacity

• Raised coil prevents debris from collecting

in bottom of coil and causing loss of airflow

COMPONENTS

• Full metal jacket panels remove with just

two screws per panel for easy coil cleaning

and service

• Filter drier installed for system protection

• Service valves positioned for quick

installation and easy service

• High and low pressure switches factory

installed

• Comfort Alert 2 diagnostics factory installed

• Charged for 15 ft. of line set

• Trade available components

DESIGN

• Designed for ambients up to 125°F

2 Stage

Compressor