![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0843.jpg)
EBRO
2017
Diagnostic work-up
T staging: CT
T stage
- based on wall thickness
and outline
•Limited soft tissue contrast
•Poor for early tumours
T Stage Wall thickness Wall Contour
T2
>3mm, <5mm Smooth
T3
5-15mm
Irregular
T4
>15mm
Contact with adjacent structure
pT2
pT4
pT3
T Staging Accuracy - 74%*
* Davies, A. R., D. A. Deans, et al. (2006). Dis Esophagus
19