Table of Contents Table of Contents
Previous Page  348 / 363 Next Page
Information
Show Menu
Previous Page 348 / 363 Next Page
Page Background

446 

C

rowley

et al

.

:

J

ournal of

AOAC I

nternational

V

ol

. 97, N

o

. 2, 2014

purified and inactivated

L. monocytogenes

receptors +

preservative + protein stabilizer.

(

e

) 

Positive control solution.—

1×3 mL. Contains purified and

inactivated

L. monocytogenes

antigen + preservative + protein

stabilizer.

(

f

) 

Negative control solution.—

1×6 mL. Contains Tris-

buffered saline (TBS; 150mmol/l) – Tween pH 7.6 + preservative.

(

g

) 

Master lot entry

(

MLE) card.—

One card providing

specifications for the factory master data required to calibrate the

test: To read the MLE data, please refer to the Operator’s Manual.

(

h

) 

Package insert

.

Table 2013.11B. Summary of results for the detection of

Listeria monocytogenes

in queso fresco (125 g)

Method

a

VIDAS LMX w/OXA

VIDAS LMX w/ALOA

Inoculation level

Uninoculated

Low

High Uninoculated

Low

High

Candidate presumptive positive/total No. samples analyzed 0/144

70/144

144/144

0/144

70/144

144/144

Candidate presumptive POD (CP)

0.00

0.49

1.00

0.00

0.49

1.00

(0.00, 0.03)

(0.40, 0.57) (0.97, 1.00)

(0.00, 0.03) (0.40, 0.57) (0.97, 1.00)

s

r

b

0.00

0.51

0.00

0.00

0.51

0.00

(0.00, 0.16)

(0.46, 0.52) (0.00, 0.16)

(0.00, 0.16) (0.46, 0.52) (0.00, 0.16)

s

L

c

0.00

0.00

0.00

0.00

0.00

0.00

(0.00, 0.16)

(0.00, 0.12) (0.00, 0.16)

(0.00, 0.16) (0.00, 0.12) (0.00, 0.16)

s

R

d

0.00

0.51

0.00

0.00

0.51

0.00

(0.00, 0.22)

(0.46, 0.52) (0.00, 0.22)

(0.00, 0.22) (0.46, 0.52) (0.00, 0.22)

P

value

e

1.0000

0.9730

1.0000

1.0000

0.9730

1.0000

Candidate confirmed positive/total No. samples analyzed

0/144

70/144

144/144

0/144

70/144

144/144

Candidate confirmed POD (CC)

0.00

0.49

1.00

0.00

0.49

1.00

(0.00, 0.03)

(0.40, 0.57) (0.97, 1.00)

(0.00, 0.03) (0.40, 0.57) (0.97, 1.00)

s

r

0.00

0.51

0.00

0.00

0.51

0.00

(0.00, 0.16)

(0.46, 0.52) (0.00, 0.16)

(0.00, 0.16) (0.46, 0.52) (0.00, 0.16)

s

L

0.00

0.00

0.00

0.00

0.00

0.00

(0.00, 0.16)

(0.00, 0.12) (0.00, 0.16)

(0.00, 0.16) (0.00, 0.12) (0.00, 0.16)

s

R

0.00

0.51

0.00

0.00

0.51

0.00

(0.00, 0.22)

(0.46, 0.52) (0.00, 0.22)

(0.00, 0.22) (0.46, 0.52) (0.00, 0.22)

P

value

1.0000

0.9730

1.0000

1.0000

0.9730

1.0000

Positive reference samples/total No. samples analyzed

0/144

69/144

144/144

0/144

69/144

144/144

Reference POD

0.00

0.48

1.00

0.00

0.48

1.00

(0.00, 0.03)

(0.39, 0.56) (0.97, 1.00)

(0.00, 0.03) (0.39, 0.56) (0.97, 1.00)

s

r

0.00

0.51

0.00

0.00

0.51

0.00

(0.00, 0.16)

(0.46, 0.52) (0.00, 0.16)

(0.00, 0.16) (0.46, 0.52) (0.00, 0.16)

s

L

0.00

0.00

0.00

0.00

0.00

0.00

(0.00, 0.16)

(0.00, 0.12) (0.00, 0.16)

(0.00, 0.16) (0.00, 0.12) (0.00, 0.16)

s

R

0.00

0.51

0.00

0.00

0.51

0.00

(0.00, 0.22)

(0.46, 0.52) (0.00, 0.22)

(0.00, 0.22) (0.46, 0.52) (0.00, 0.22)

P

value

1.0000

0.9672

1.0000

1.0000

0.9672

1.0000

dLPOD (C vs R)

0.00

0.01

0.00

0.00

0.01

0.00

(–0.03, 0.03) (–0.10, 0.13) (–0.03, 0.03)

(–0.03, 0.03) (–0.10, 0.13) (–0.03, 0.03)

dLPOD (CP vs CC)

0.00

0.00

0.00

0.00

0.00

0.00

(–0.03, 0.03) (–0.12, 0.12) (–0.03, 0.03) (–0.03, 0.03) (–0.12, 0.12) (–0.03, 0.03)

a

 Results include 95% confidence intervals.

b

 Repeatability standard deviation.

c

 Among-laboratory standard deviation.

d

 Reproducibility standard deviation.

e

P

value = Homogeneity test of laboratory PODs.

Candidates for 2016 Method of the Year