One non-target strain,

E. coli

ATCC 25922,was tested at a high level inoculum level (target 150 cfu/mL).

1

For the yeast

Candida troplicalis

, five replicates were inoculated to Petrifilm RYM Plates achieve the

2

target level of approximately 50-100 CFU/mL for high level and 10-20 CFU/ml for the low level. For

E.

3

coli

, five replicates were inoculated to achieve target levels of 100-150 CFU/mL for the high level

.

The

4

plates were incubated at 25 ± 1

º

C for 48 hours and then the colonies were enumerated.

5

6

Table 4.

Summary of Combined Shelf Life and Lot-to-Lot Consistency for

Geotrichum candidum

at the

7

Low Inoculation Level.

8

DRBC Raw

Count

Log

10

Petrifilm

2014-01 KA

Raw Count

Log

10

Petrifilm 2014-

01 KB Raw

Count

Log

10

Petrifilm 2014-

01 KC Raw

Count

Log

10

14

1.146

17

1.230

21

1.322

13

1.114

24

1.380

14

1.146

11

1.041

21

1.322

15

1.176

17

1.230

21

1.322

20

1.301

18

1.255

15

1.176

13

1.114

16

1.204

18

1.255

15

1.176

14

1.146

15

1.176

1.243

1.192

1.189

1.223

t-test 0.422

0.608

0.631

9

10

Table 5.

Summary of Combined Shelf Life and Lot-to-Lot Consistency for

Geotrichum candidum

at the

11

High Inoculation Level.

12

DRBC Raw

Count

Log

10

Petrifilm 2014-

01 KA Raw

Count

Log

10

Petrifilm 2014-

01 KB Raw

Count

Log

10

Petrifilm

2014-01 KC

Raw Count

Log

10

43

1.633

42

1.623

47

1.672

58

1.763

45

1.653

55

1.740

48

1.681

54

1.732

54

1.732

46

1.663

51

1.708

45

1.653

33

1.519

48

1.681

50

1.699

50

1.699

40

1.602

56

1.748

57

1.756

46

1.663

1.628

1.691

1.703

1.702

t-test 0.232

0.128

0.164

13

14

15

16

17

18

19

20

21

22

Table 6.

Summary of Combined Shelf Life and Lot-to-Lot Consistency for

Candida tropicalis

at the Low

23

Inoculation Level.

24

9

AOAC Research Institute

Expert Review Panel Use Only

OMAMAN-16D/ PTM Report

ERP Use Only - December 2014