![Show Menu](styles/mobile-menu.png)
![Page Background](./../common/page-substrates/page0909.png)
SUBMITTED 050113
Appendix I. Instructions to Collaborators
Instructions to Collaborators
ANSR
Salmonella
Confirmation Test
Thank you for agreeing to participate in this AOAC inter-laboratory collaborative study. Please review
this document carefully, as it contains essential information regarding receipt and handling of test
samples, materials required, testing procedures, and data reporting. If you have questions at any time
prior to or during the course of the study, please contact the Study Director:
Dr. Mark Mozola
(517) 372-9200 ext. 4426
mmozola@neogen.comMaterials Required
The following materials will be provided by Neogen Corp.:
1.
ANSR
Salmonella
test kit, cat. no. 9820 (store at 2-8
o
C)
2.
ANSR Reader with computer and software, cat. no. 9828/9832
3.
Heater block, 80 + 2
o
C, cat. no. 9826
4.
8-channel pipettor and filtered tips, 10-100 µL, cat. no. 9388/9389
5.
Hektoen enteric agar (HE), 500 g
6.
Xylose lysine deoxycholate agar (XLD), 500 g
7.
Bismuth sulfite agar (BS), 500 g
8.
Brilliant green sulfa agar (BGS), 500 g
9.
Xylose lysine tergitol agar (XLT4), 500 g
10.
Double-modified lysine iron agar (DMLIA), 500 g
11.
Tryptic soy agar (TSA), 500 g
Other materials required but not supplied:
1.
Pipettor, 20-200 µL
2.
Pipettor, 100-1,000 µL
3.
Pipette tips, 100-1,000 µL
4.
Test tubes, sterile, capped, for 0.5 mL sample volume (e.g., 12 x 75 mm)
5.
Inoculating loops or needles
6.
Petri dishes
10