Table of Contents Table of Contents
Previous Page  343 / 596 Next Page
Information
Show Menu
Previous Page 343 / 596 Next Page
Page Background

5

1

2

3

4

5

6

AOAC Official Method 2016.xxx

7

Listeria

speciesin SelectFoods and Environmental Surfaces

8

3M

Molecular Detection Assay(MDA) 2-

Listeria

Method

9

First Action 2016

10

11

(Applicable to detection of

Listeria

speciesin hot dogs (25g & 125g), salmon (25g), deli turkey

12

(25g & 125g), cottage cheese (25g), vanilla ice cream (25g), queso fresco (25g), spinach (25g),

13

melon (whole), raw chicken leg pieces (25g), raw chicken fillet (25g); concrete (3M™ Hydrated

14

Sponge Stick with D/E, 225 mL & 100 mL), stainless steel (3M™ Hydrated Sponge Stick with

15

D/E, 225 mL), and plastic (3M™ Enviro

sS

wab with Letheen, 10 mL) environmental samples.

16

17

See Tables

2016.1A

and

2016.1B

for a summary of results of the inter-laboratory study.

18

See Tables

2016.2A

and

2016.2B

for detailed results of the inter-laboratory study

19

20

A.

Principle

21

22

The 3M

Molecular Detection Assay (MDA) 2 -

Listeria

method is used with the 3M

23

Molecular Detection System (MDS) for the rapid and specific detection of

Listeria

in enriched

24

food and food process environmental samples. The 3M MDA2 -

Listeria

uses loop-mediated

25

isothermal amplification of unique DNA target sequences with high specificity and sensitivity,

26

combined with bioluminescence to detect the amplification. Presumptive positive results are

27

reported in real-time while negative results are displayed after the assay is completed. Samples

28

arepre-enriched in Demi Fraser broth with ferric ammonium citrate (FAC).

29

30

B.

Apparatus and Reagents

31

Items (b)-(g) are available as the 3M

Molecular Detection Assay (MDA) 2 -

Listeria

kit

32

from 3M Food Safety (St. Paul, MN 55144-1000, USA).

33

(a)

3M Molecular Detection System

(MDS100) – Available from 3M Food Safety (St.

34

Paul, MN 55144-1000, USA).

35

(b)

3M Molecular Detection Assay 2 – Listeria reagent tubes-

12 strips of 8 tubes.

36

Available from 3M Food Safety (St. Paul, MN 55144-1000, USA).

37

(c)

Lysis Solution (LS) tubes –

12 strips of 8 tubes.

38

(d)

Extra caps

– 12 strips of 8 caps

39

(e)

Reagent Control –

8 reagent tubes

40

(f)

Quick Start Guide

41

(g)

3M

Molecular Detection Speed Loader Tray -

Available from 3M Food Safety

42

(St. Paul, MN 55144-1000, USA).

43

(h)

3M

Molecular Detection Chill Block Insert

- Available from 3M

Food Safety (St.

44

Paul, MN 55144-1000, USA).

45

(i)

3M

Molecular Detection Heat Block Insert

- Available from 3M Food Safety

46

(St. Paul, MN 55144-1000, USA).

47

(j)

3M

Molecular Detection Cap/Decap Tool for Reagent tubes

- Available from 3M

48

Food Safety (St. Paul, MN 55144-1000, USA).

49