Table of Contents Table of Contents
Previous Page  179 / 453 Next Page
Information
Show Menu
Previous Page 179 / 453 Next Page
Page Background

Page

1

of

17

Independent Laboratory Evaluation of the

3M™ Molecular Detection Assay 2 -

E. coli

O157:H7

for the Detection of

E. coli

O157:H7 in Raw Ground Beef

The 3M

Molecular Detection Assay 2 (MDA 2) –

E. coli

O157 (including H7) employs

real-time isothermal technology for the rapid and accurate detection of

E. coli

O157

(including H7) from select food matrices. This study included a method comparison

evaluation of the 3M MDA 2 –

E. coli

O157:H7 to the USDA/FSIS-MLG 5.09

Detection,

Isolation and Identification of Escherichia coli O157:H7 from Meat Products and

Carcass and Environmental Sponges

for the detection of

E. coli

O157:H7 in raw ground

beef (73% lean). The 3M MDA 2 –

E. coli

O157:H7 was evaluated for its ability to

accurately detect

E. coli

O157:H7 from raw ground beef after 10 hours of incubation.

In the method comparison study, the 3M

MDA 2 -

E. coli

O157:H7 demonstrated no

statistically significant differences between presumptive and confirmed results (dPOD

CP

)

or between candidate and reference method results (dPOD

C

) for the evaluation of the

raw ground beef matrix.

Study Report Authors

Alison DeShields, Benjamin Bastin, Patrick Bird, M. Joseph Benzinger, Jr., Erin

Crowley, James Agin, and David Goins

Q Laboratories, Inc., Cincinnati, OH, USA 45214

Submitting Company

3M

Food Safety Department

3M

Center

Building 260-6B-01

St. Paul, MN 55144

Independent Laboratory

Q Laboratories, Inc.

1400 Harrison Ave

Cincinnati, OH 45214

United States

Scope of Methods

(a) Target organism – E. coli

O157

(b) Matrix