Table of Contents Table of Contents
Previous Page  240-241 / 453 Next Page
Information
Show Menu
Previous Page 240-241 / 453 Next Page
Page Background

27

Table 2016.2A (cont’d.)

: Comparative Results for the Detection of

E. coli

O157 in 325 g Raw Ground Beef (73% Lean) Test Portions by the

mericon

E.

1

coliO157Screen Plususing manual extraction vs. USDA/FSIS MLG 5.09 in a Collaborative Study(Low Inoculum Level)

2

Statistic

Matrix/

Inoculation

Level

Laboratory

Candidate presumptive

(CP)

Candidate confirmed (CC)

Candidate result (C)

Reference method (R)

C vs. R

N

X

POD

(CP)

N

X

POD

(CC)

N

X

POD

(C)

N

X

POD

(R)

dLPOD

(C,R)

dLPOD

(CP,CC)

Raw

Ground

Beef

1

12

5

0.42

12

5

0.42

12

5

0.42

12

5

0.42

0.00

0.00

2

a

NA NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

NA

3

12

7

0.58

12

7

0.58

12

7

0.58

12

7

0.58

0.00

0.00

4

12

6

0.50

12

6

0.50

12

6

0.50

12

6

0.50

0.00

0.00

5

12

6

0.50

12

5

0.42

12

5

0.42

12

5

0.42

0.00

0.08

6

12

4

0.33

12

4

0.33

12

4

0.33

12

4

0.33

0.00

0.00

7

12

7

0.58

12

6

0.50

12

6

0.50

12

6

0.50

0.00

0.08

8

12

5

0.42

12

5

0.42

12

5

0.42

12

5

0.42

0.00

0.00

9

12

5

0.42

12

5

0.42

12

5

0.42

12

5

0.42

0.00

0.00

10

12

9

0.75

12

8

0.67

12

8

0.67

12

8

0.67

0.00

0.08

MPN/

Test

Portion

0.62

0.48

0.77

11

12

7

0.58

12

6

0.50

12

6

0.50

12

6

0.50

0.00

0.08

12

12

3

0.25

12

3

0.25

12

3

0.25

12

3

0.25

0.00

0.00

13

12

5

0.42

12

5

0.42

12

5

0.42

12

5

0.42

0.00

0.00

Estimate

All

144

69

0.48

144

65

0.45

144

65

0.45

144

65

0.45

0.00

0.03

LCL

0.40

0.37

0.37

0.37

-0.12

-0.09

UCL

0.56

0.54

0.54

0.54

0.12

0.15

s

r

b

0.50

0.51

0.51

0.51

LCL

0.45

0.45

0.45

0.45

UCL

0.52

0.52

0.52

0.52

s

L

c

0.00

0.00

0.00

0.00

LCL

0.00

0.00

0.00

0.00

UCL

0.18

0.15

0.15

0.15

s

R

d

0.50

0.51

0.51

0.51

UCL

0.45

0.46

0.46

0.46

LCL

0.52

0.52

0.52

0.52

P

T

e

0.5820

0.8479

0.8479

0.8479

a

N/A – Laboratory did not participate or submit data for this matrix

3

b

Repeatability Standard Deviation,

c

Among-Laboratory Standard Deviation,

d

Reproducibility Standard Deviation,

e

P

T

Value = Homogeneity test of laboratory PODs

4

LCL – Lower Confidence Limit; UCL – Upper Confidence Limit

5

6

7

OMAMAN-36 A : Collaborative Study Manuscript

For ERP Use Only

January 2017

AOAC Research Institute