Inter Terminals Ltd. - Tyne Terminal
Tank 24 Road Loading Overspill System – I.S. Calculation
P & I Design Ltd
DOCUMENT NO: 16115CAL001
2 Reed Street, Thornaby, UK, TS17 7AF
ISSUE: A
Tel: + 44 (0) 1642 617444
DATE: 02/02/17
Fax: + 44 (0) 1642 616447
PAGE: Page 7 of 8
www.pidesign.co.uk3.3
Inductive Sensor
Manufacturer: Pepperl+Fuchs
Model: NCB15-30GM40-N0-V1
Certification: ExII 1G EEx ia IIC T6
Certificate No.: PTB 00 ATEX 2048 X
Supplement 6 to the ATEX Certificate confirms that this model of sensor falls into
Category 1.
This sensor cannot be classified as Type 1 from the ATEX Certificate as the power supplied
by the isolator (45mW) is higher than the input power for Type 1 (34mW). Type 2 satisfies
input voltage, current and power considerations as well as giving a very conservative
ambient temperature limit of 52°C to achieve T6
The data collected from the ATEX certificates for use in 16115CAL002 and
16115CAL003 has been highlighted below.
Figure 3: Data from Supplement 6 to the ATEX Certificate PTB 00 ATEX 2048 X. Yellow
highlighting shows data used.