1

MAX

MAX

Shield grounding bar

Main Earth Terminal

II

1 G

ia IIC T6

Ex II ( 1 ) G D [EEx ia ] IIC

V

mA

W

Cc2:

μF/km =>

μF Cc1:

μF/km =>

μF Cct:

μF

µF

Lc2:

2 x

mH/km =>

mH Lc1:

2 x

mH/km =>

mH Lct:

mH

mH

Lc2/Rc2:

mH/

W

Lc1/Rc1:

mH/

W

Lct/Rct:

W

Rc2:

2 x

W

/km =>

W

Rc1:

2 x

W

/km =>

W

Rct:

W

W

0

0

0 0 0

1

0

-1 0 0

IIB IIC 2 3

IIB

IIC

11 # 22 IIC

T4 4 6

T4

T6

6 #

6 ## 6 T6

Uo

V

V

Io

mA

mA

Po

W

W

Co

µF

µF

Lo

mH

mH

Lo/Ro

Lct/Rct

(Ci+Cct) Ceq

(Li+Lct) Leq

L/R

Resistance

Plant Zone Elect.

Inst. Zone Elect.

EEx

I current

Power

Capacitance

Inductance

Ii:

Certification

mA

0.06

0.0000

TÜV 03 ATEX 2003 X

Ui

Ii

Li:

V

Pi

Final calculation result

>

Lo:

Ro:

CP2/FJB27

BS5308 Part 1 Type 2

121.5

10.5

2.4100

5.9040

0.040

0.9840

24.600

147.600

Uo:

Io:

Po:

Co:

0.1150

Sheet :

of

5000

1000

CABLE 2

JUNCTION BOX

2 X 2 X 1.5mm

2

EEx-i ISO

LATOR

CABLE 1

BASEEFA 06 ATEX 0092

17

0.045

Multiple twisted pairs - SWA armoured

Pepperl+Fuchs

SWITCH

AMPLIFIER

ISOLATOR

Date

App

BY Check

IIB

T4

16115CAL002

SAFE

AREA

DJH MM MM 02.02.17

CAPACITIVE SENSOR

AND SWITCH AMPLIFIER ISOLATOR

Temperature Class

Gas Group

HAZARDOUS AREA

INTRINSICALLY SAFE

CIRCUIT CALCULATION

Calculation

N° :

INTER TERMINALS LTD

TYNE TERMINAL

A

Rev

16115

VERIFIED

OK

>

>

OK

OK

OK

THIS VERIFICATION IS NOT NECESSARY AS THE OTHER RELATIONSHIPS (CAPACITANCE, INDUCTANCE AND RESISTANCE) ARE VERIFIED

<

<

16.0

25

0.06

<

10.5

17.1

121.5

0.75000

2.4100

OK

OK

5.90400

12.30

4.9200

0.040

123.00

Supply by

Inter Terminals

Cable 2

Plant Temp Class

Inst. Temp Class

Plant Zone Process

Inst. Zone Process

Plant Gas Group Inst. Gas Group

0.0600

Ex

<

>

Ri:

Ui:

Pi:

Ci:

0.115

16.0

25

µF

mH

Verification Calculations

0.4920

12.30

0.4920

0.5750

OK

OK

<

OK

OK

0.045

1

Verification Checks

Cable Calculations:

Leq = (Cable mH/km x 2 x Cable Length in m /1000) + Field Instrument mH

Ceq = (Cable μF/km x Cable Length in m /1000) + Field Instrument Μf

SI347001_DWG_REVD

Zone

0

KCD2-SR-Ex2

Switch Amplifier

Pepperl+Fuchs

CJ4-12GK-N

Capacitive sensor

0.6900

Certificate No.

Voltage

Specification

Manufacturer

Model

Description

Cable 1

W

0.115

BS5308 Part 1 Type 2

Multiple twisted pairs - SWA armoured

Cable 1 + Cable 2

Inter Terminals

P&F

CAPACITIVE

SENSOR

Loop Sheet No.

1

Process Electronics

10 X 2 X 1.5mm

2

EEx-(ia) SENSOR

FJB27