Instrument

GC/LC column Column specification

GC column

temperature

LC gradient program SPE cartridge

The comprehensive instrument, analyticalparameters and SPE cartridge of AOAC collaborative study

Technicalconditions

GC-MS (16 Labs)

GC-MS/MS(15 Labs)

LC-MS/MS (24 Labs)

Instrument

22

5 types: Agilent; Varian

5 types: Agilent; Waters; Thermo Fisher and

Bruker

12 types: Agilent; SHIMADZU; Waters and

Thermo Fisher

Chromatographic column

27

5 brands

DB-1701;Restek Rtx 1701; MR2; HP-5

ms; HP-5MSUI

8 brands

DB-1701;HP-5 ms; HP-5MSUI; HP-5MSI;

DB-5MSUI; DB5-MS; BR-5ms; Rxi 5 Sil

14 brands

ZORBAXSB-C18;phenomenex Luna C8; Waters

Atlantis C18; phenomenex Luna C18

Specification

19

30m×0.25mm×0.25μm

3 Specification

30m×0.25mm×0.25μm; 15m×0.25mm×0.25μm;

length20m/Diam. 0.180mm/Film 0.18µm

15 Specification

3.5 μm×100mm ×2.1mm;

3.5μm×150mm×2.1;150mm×2.00mm×3μm

GCcolumn

temperature (14)

LCgradient

program(11)

5 GC column temperature

40℃ hold 1 min , at 30℃/min to 130℃,

at 5℃/min to 250℃, at 10℃/min to 300

℃, hold 5 min

9 GC column temperature

40℃ hold 1 min , at 30℃/min to 130℃, at

5℃/min to 250℃, at 10℃/min to 300 ℃, hold

5 min

11 GC column temperature :

0min-99%A, 3 min-70% A, 6 min-60% A, 9 min-

60%A, 15 min -40% A, 19 min -1% A, 23 min -1%

A, 23.01 min -99% A

SPE cartridge(12)

3 SPE cartridges

CleanertTPT; UCT (ECPSACB506);

Envicarb/PSA

4 SPE cartridges

CleanertTPT; InertSep GC/PSA; Agilent

Technolongies BE

Carbon 500mg/PSA; Envi Carb/PSA

5 SPE cartridges

CleanertTPT; InertSep GC/PSA; Agilent

Technolongies BE Carbon 500mg/PSA; Envi-

Carb; Envi Carb/PSA

Comprehensive technical conditions were used by 30 Labs

6742

40586

22879

2193

8915

0

5000

10000

15000

20000

25000

30000

35000

40000

45000

Results of target

pesticides

Monitoring ions

Ion abundance

Calibration curve

Results of pre-

collaborative study

Five types of data

30 laboratories have submitted to SD clusters of data totaling 81315

the method efficiency can be evaluated comprehensively with these five classes of data, and

errors can be analyzed and traced. In addition, it also includes a 5000-page of raw data reports

and chromatographs.

A lot of outliers obtained by one out of 30 laboratories were eliminated because of its digression from the

operation protocol, so this laboratory’s data was excluded from the evaluation of the method that ensued.