Table of Contents Table of Contents
Previous Page  804 / 1003 Next Page
Information
Show Menu
Previous Page 804 / 1003 Next Page
Page Background

RD-3-9098-0 (REV B)

PAGE 3

4.

Black/White Wire: Connect to compressor clutch. Route the wire around the hinge point before

connecting to compressor clutch on tilt-cab installations.

5.

If clutch does not engage the system may not have been charged to high enough pressure to

actuate the pressure switch. Place a jumper wire across the switch to start system.

6.

See Wiring Schematic provided in installation kit (RD-3-9094).

ROOFTOP AIR CONDITIONER INSTALLATION

Figure 2

R-9757 Unit

Ensolite Gaskets

See RD-3-9076-0

RD-3-9075-0

Conditioned Air Outlets

Recirc Air

Reinforce &

Mount Stiffeners

Air Distributor

Plastic Plenum

& Control Panel

Apply Sealant

& Rubber Washers

to ALL Mounting

Bolt Holes

M6 x 1.0 Screw

(4 places)

3/8-16 Screw

(10 places)

3/8 Washer

ALL Flanges

are down

(Hidden)