RD-3-9098-0 (REV B)
PAGE 3
4.
Black/White Wire: Connect to compressor clutch. Route the wire around the hinge point before
connecting to compressor clutch on tilt-cab installations.
5.
If clutch does not engage the system may not have been charged to high enough pressure to
actuate the pressure switch. Place a jumper wire across the switch to start system.
6.
See Wiring Schematic provided in installation kit (RD-3-9094).
ROOFTOP AIR CONDITIONER INSTALLATION
Figure 2
R-9757 Unit
Ensolite Gaskets
See RD-3-9076-0
RD-3-9075-0
Conditioned Air Outlets
Recirc Air
Reinforce &
Mount Stiffeners
Air Distributor
Plastic Plenum
& Control Panel
Apply Sealant
& Rubber Washers
to ALL Mounting
Bolt Holes
M6 x 1.0 Screw
(4 places)
3/8-16 Screw
(10 places)
3/8 Washer
ALL Flanges
are down
(Hidden)