Submission Date
Name
Organization
Title of Method
AOAC Candidate Method
Number (e.g. ALN-01)
Applicable SMPR
I. General Summary:
1. Does the applicability of
the method support the
applicability of the SMPR? If
not, please explain what is
missing.
2. Does the analytical
technique(s) used in the
method meet the SMPR? If
not, please specify how it
differs from what is stated in
the SMPR.
AOAC SPSFAM ERP REVIEW FORM - MARCH 13, 2017
2017-03-01 19:29:16
SNEH BHANDARI
sneh.bhandari@mxns.comSilliker Laboratories
Detection and Quantitation of Selected Food Allergens using LC-MS/MS (Revision 2)
ALL-01
2016.002
A LC-MS/MS based method for the detection and quantitation of whole egg (egg white
and egg yolk), whole milk, peanut butter, and hazelnut commodity in food matrices
listed in AOAC SMPR 2016.002 was developed and tested. The method uses triple
quadrupole mass spectrometry and Multiple Reaction Monitoring (MRM) of
characteristic transitions of precursor ions to fragment ions of a marker peptides to
uniquely identify each allergen. The calibration curves were plotted using the ratio of
unique peptide peak area of each allergen commodity in food matrix to spiked labeled
internal standard (area ratio) against incurred or spiked commodity concentration. The
recoveries (%) for each allergen commodity were estimated (n=9). The same quantifier
ion was used for the different food matrices except chocolate and wine due to matrix
interference or non-specific binding for certain proteins or peptides. The sensitivity and
selectivity of the method are demonstrated.. Overall, the method was able to meet the
method performance requirements stated in AOAC SMPR 2016.002. For all food
matrices, the target commodity analytical range of 10
‒
1000 ppm was achievable and
the method demonstrated good repeatability with RSDr < 15% . Except for chocolate,
the peptide recoveries ranged from 60.5 to 109.9% in the tested food matrices. The
method is able to demonstrate good sensitivity and is able to detect whole egg and the
rest of the allergen commodities at a MQL of 3 or 10 ppm, respectively. Similar results
were also achieved for the qualifier ion. Except for quantifier ion, poor sensitivity (MQL
≤ 30%) and low recovery (< 60%) were observed for the qualifier ions of milk, peanut
and hazelnut in chocolate due to severe matrix effects. The scope of the method is
limited to these matrices and allergen commodities.
SMPR states detection and quantitation of egg, milk, peanut, and hazelnut food
allergens in finished food products and ingredients. The submitted method is able to
detect mentioned allergens in selected matrices. Egg white and egg yolk in Cookies,
bread, cookie dough, salad dressing and white wine. Whole milk in cookies, infant
formula, red wine and dark chocolate. Peanut and hazelnut in cookies, ice cream,
breakfast cereals and milk chocolate. The method has not been applied to different
varieties of specified matrices in respective allergen category.
Yes.
II. Review of the
Method Only: