Mai„ Offic: 405-631-9701

960

Fax: 405-631-0585

T

|

TOOLS

DIGITAL STICK METER

WITH NON-CONTACT VOLTAGE

Auto-Ranging

Analog Bar Graph

Temperature

Non-contact Votage

Microamps

Frequency

Capacitance

Rugged Case

Hi-Voltage Indicators

Auto Power Off

Backlight

True RMS

Every HS30 series meter comes packaged

inside the padded ANC1 4-pocket case. A

300AAC clamp head (ACH) is included. Just

slide the clamp onto the top of the HS30

meter to read amps. Also included are deluxe

silicone test leads, alligator clips, k-type

thermocouple (HS33, HS35, HS36), battery

(installed), operator’s manual, and RFM66

fuse (installed).

Test Lead Solutions

• Probe storage in the back

• Removable probe tips for connection to

most accessory heads.

• Attach detachable probe tip directly into jack

for easy and safe voltage testing.

• Leads conveniently wrap around meter.

Locke#

T1450

HS36-K11 Digital Stick Meter

T1462

RFM66(4) Fuse for HS-36

ELECTRONIC HANDLE

Converts Every Fieldpiece Accessory Head

into a Stand Alone Meter

Locke#

T1457

EHDL1 Electronic Handle

MILLIAMPS & MICROAMP

ACCESSORY

• Measures milliamps and microamps for

flame diode test. Measures 4 to 20mA

control circuits.

• Includes flame diode adapter kit (AQK3).

• Resolution: 0.1 for meters with 0.1mVDC.

• Accuracy: DC: ±(1.0%rdg + 1dgt) AC:

±(1.5% + 2dgts).

• Max current: 200mA AC or DC.

Locke#

T1772

AUA2 Milliamps & Microamp

Accessory

400A AMP CLAMP

ACCESSORY

The claw feature at the top of the clamp allows

for quickly picking out the wire you need to

measure and isolating it in the clamp. Once

the current carrying conductor is isolated, the

amperage is converted to mVAC for reading

directly on the meter. The ACH4 works with

the Fieldpiece “Stick” meter, EHDL1 Electronic

Handle, DL3 Data Logger, the HG2 HVAC

Guide® System Analyzer or any other digital

multimeter (with mVAC range) connected by

Fieldpiece ADLS2 detachable silicone leads

or AHDL1 handle adapter.

Locke#

T1775

ACH4 400A Amp Clamp

Accessory

METERS WITH ACCESSORY HEADS

A/C SUPERHEAT &

SUBCOOLING HEAD

Measures refrigerant

pressure and temperature

and calculates superheat

or subcooling for R22 and

R410A.

• Display pressure

• Display temperature

• Display superheat

• Display subcooling

• Select R22 or R410A.

• Auto-off can be disabled for data logging.

NEW FEATURES

• Includes "T".

• Now accepts K-type thermocouples. ATC1

included.

• LED indicates when readings are stable.

• Thermocouple calibration pot.

• Atmosphere pressure calibration.

Locke#

T1656

ASX14 Superheat & Subcooling

Head

CARBON MONOXIDE

HEAD & PUMP

Measures CO in air and finds sources.

• Fast enough to locate CO source in “walk-

around” test.

• Three pin sensor for better performance.

• Select averaging or normal for smoothing or

fast response to change.

• Range: 0 to 1000PPM (2000PPM with 5

minute max exposure time).

• Initial accuracy: 0-15ppm ±5% reading ±1

ppm after zeroing;15-35ppm ±5% reading

±2 ppm after zeroing;

0-1000ppm ±5% reading ±5 ppm after

zeroing.

• Response time: <70sec to 90%of reading.

• Operating temperature: 32 to 105 ºF.

Locke#

T1657

ACMK3 CO Head