5/77

Articles marked ◊ are not held in stock, procurement is effected at short notice.

5

Hand Tools

Design:

Casing made of impact-resistant plastic.

Application:

For the measuring of DC and AC voltages as well as current and resistance,

frequency and capacity, continuity and diode testing.

Order No.

0005

0005

0050

0100

0251

Model

MM 1

MM 2

MM 3

MM 4

MM 7-1

5584

76.00

5587

90.30

114.00

130.80

202.30

DC voltage

0.1 mV–600 V

0.1 mV–1000 V

0.1 mV–600 V

1 mV–600 V

10 µV–1000 V

AC voltage

1 mV–600 V

0.1 mV–750 V

0.1 mV–600 V

1 mV–600 V

10 µV–1000 V

Direct current

0.1 µA–3.2 mA

0.1 µA–20 A

0.1 µA–20 A

10 µA–10 A

Alternating current

0.1 µA–20 A

0.1 µA–20 A

0.1 A–300 A

10 µA–10 A

Resistance

0.1 Ohm–32 MOhm 0.1 Ohm–20 MOhm 0.1 Ohm–20 MOhm 0.1 Ohm–42 MOhm 0.1 Ohm–40 MOhm

Continuity/diodes

yes/yes

yes/yes

yes/yes

yes/yes

yes/yes

Frequency

1 Hz–200 kHz

0.01 Hz–100 kHz

Capacity

1 pF–200 µF

1 nF–10 mF

Temperature

–40 °C to +400 °C

Pliers opening

30mm

Measurement category

CAT III 600 V

CAT III 600 V

CAT III 300 V

CAT III 300 V

CAT IV 600 V

Measuring procedure

RMS

RMS

RMS

RMS

TRUE RMS

Protection type

IP 30

IP 30

IP 30

IP 30

IP 30

Batteries

2 x micro AAA/LR03 1 x 6LR61 block battery 1 x 6LR61 block battery 2 x micro AAA/LR03 1 x 6LR61 block battery

Display

LCD

LCD

LCD

LCD

LCD

(514)

Digital multimeter

IP 30

5584

MM 1

Supplied with protective rubber case, compact protective bag,

dual-insulated safety measurement lines and batteries.

5587

MM 2

Supplied with protective rubber case, compact protective bag,

dual-insulated safety measurement lines and batteries.

0005

5587

MM 3

Supplied with protective rubber case, compact protective bag,

dual-insulated safety measurement lines and batteries.

0050

5587

MM 4

Supplied with AC current pliers attachment, measuring probes, compact

protective bag, dual-insulated safety measurement lines and batteries.

0100

5587

MM 7-1 Automatic voltage function for automatic identification of DC/AC

voltage, low input impedance (LoZ) for the suppression of capacitive/inductive

interspersed voltages.

Supplied with wire temperature sensor with adapter, rubber

protective case, compact protective bag, dual-insulated safety measurement lines as

well as batteries.

0251

CAT

IV

CAT

III

CAT

III

CAT

III

CAT

III

5587 0251

5587 0100

5587 0050

5587 0005

5584 0005

0005

The measurement categories

CAT I to CAT IV

CAT I valid for measurements performed on circuits not

directly connected to the network (e.g. specially

protected devices)

CAT Il Valid for measurements in building installation

(e.g. distribution, wiring, sockets, switches)

CAT III Valid for measurements in the building installation

(e.g. distribution, wiring, sockets, switches)

CAT IV Valid for measurements at the source of low-voltage

installations (e.g. counters, main terminal, primary

excess current protection devices).

Y

1

distribution

Y

2

counter

Y

3

outside trans-

former station

Y

4

underground

cables

Test and measuring devices

Not all items are available in every country.