5/77
Articles marked ◊ are not held in stock, procurement is effected at short notice.
5
Hand Tools
Design:
Casing made of impact-resistant plastic.
Application:
For the measuring of DC and AC voltages as well as current and resistance,
frequency and capacity, continuity and diode testing.
Order No.
0005
0005
0050
0100
0251
Model
MM 1
MM 2
MM 3
MM 4
MM 7-1
5584
76.00
–
–
–
–
5587
–
90.30
114.00
130.80
202.30
DC voltage
0.1 mV–600 V
0.1 mV–1000 V
0.1 mV–600 V
1 mV–600 V
10 µV–1000 V
AC voltage
1 mV–600 V
0.1 mV–750 V
0.1 mV–600 V
1 mV–600 V
10 µV–1000 V
Direct current
0.1 µA–3.2 mA
0.1 µA–20 A
0.1 µA–20 A
–
10 µA–10 A
Alternating current
–
0.1 µA–20 A
0.1 µA–20 A
0.1 A–300 A
10 µA–10 A
Resistance
0.1 Ohm–32 MOhm 0.1 Ohm–20 MOhm 0.1 Ohm–20 MOhm 0.1 Ohm–42 MOhm 0.1 Ohm–40 MOhm
Continuity/diodes
yes/yes
yes/yes
yes/yes
yes/yes
yes/yes
Frequency
–
–
1 Hz–200 kHz
–
0.01 Hz–100 kHz
Capacity
–
–
1 pF–200 µF
–
1 nF–10 mF
Temperature
–
–
–
–
–40 °C to +400 °C
Pliers opening
–
–
–
30mm
–
Measurement category
CAT III 600 V
CAT III 600 V
CAT III 300 V
CAT III 300 V
CAT IV 600 V
Measuring procedure
RMS
RMS
RMS
RMS
TRUE RMS
Protection type
IP 30
IP 30
IP 30
IP 30
IP 30
Batteries
2 x micro AAA/LR03 1 x 6LR61 block battery 1 x 6LR61 block battery 2 x micro AAA/LR03 1 x 6LR61 block battery
Display
LCD
LCD
LCD
LCD
LCD
(514)
Digital multimeter
IP 30
5584
MM 1
Supplied with protective rubber case, compact protective bag,
dual-insulated safety measurement lines and batteries.
5587
MM 2
Supplied with protective rubber case, compact protective bag,
dual-insulated safety measurement lines and batteries.
0005
5587
MM 3
Supplied with protective rubber case, compact protective bag,
dual-insulated safety measurement lines and batteries.
0050
5587
MM 4
Supplied with AC current pliers attachment, measuring probes, compact
protective bag, dual-insulated safety measurement lines and batteries.
0100
5587
MM 7-1 Automatic voltage function for automatic identification of DC/AC
voltage, low input impedance (LoZ) for the suppression of capacitive/inductive
interspersed voltages.
Supplied with wire temperature sensor with adapter, rubber
protective case, compact protective bag, dual-insulated safety measurement lines as
well as batteries.
0251
CAT
IV
CAT
III
CAT
III
CAT
III
CAT
III
5587 0251
5587 0100
5587 0050
5587 0005
5584 0005
0005
The measurement categories
CAT I to CAT IV
CAT I valid for measurements performed on circuits not
directly connected to the network (e.g. specially
protected devices)
CAT Il Valid for measurements in building installation
(e.g. distribution, wiring, sockets, switches)
CAT III Valid for measurements in the building installation
(e.g. distribution, wiring, sockets, switches)
CAT IV Valid for measurements at the source of low-voltage
installations (e.g. counters, main terminal, primary
excess current protection devices).
Y
1
distribution
Y
2
counter
Y
3
outside trans-
former station
Y
4
underground
cables
Test and measuring devices
Not all items are available in every country.
947