5

Hand Tools

Design:

Housing made of impact-resistant, unbreakable plastic, with automatic shutdown

function.

Application:

For the safe current measurement at insulated cables, without having to remove

or damage the insulation.

Order No.

0101

0102

0200

0501

0700

Model

CM 1-1 CM 1-2

CM 2

CM 5-1

CM 7

5585

59.60

79.70

170.90

247.00

265.90

DC voltage

– 0.1 V–600 V 1 mV–600 V 0.7 V–1000 V 0.1 V–1000 V

AC voltage

– 0.1 V–600 V 0.1 mV–

600 V

1.3 V–750 V 0.1 V–750 V

Direct current

10 mA–

300 A

0.9 A–600 A 0.1 A–1000 A

Alternating current

10 mA–

400 A

0.1 A–400 A 100 mA–

300 A

0.9 A–600 A 0.1 A–1000 A

Resistance

0.1 Ohm–

20 MOhm

0.1 Ohm–

40 MOhm

1 Ohm–

10 kOhm

0.1 Ohm–

400 Ohm

Continuity

yes

yes

yes

yes

Frequency

1 Hz–400 Hz

Measured data storage

HOLD, MAX HOLD HOLD, MAX HOLD HOLD, MAX/

MIN, PEAK,

ZERO

Measuring procedure

RMS

RMS TRUE RMS TRUE RMS TRUE RMS

Pliers opening

30 mm 30 mm 25 mm 35 mm 53 mm

Measurement category

CAT III 600 V CAT III 600 V CAT III 300 V CAT IV 600 V CAT IV 600 V

Protection type

IP 30

IP 30

IP 30

IP 30

IP 30

Batteries

1 x 6LR61

block

battery

2 x micro

AAA/LR03

2 x micro

AAA/LR03

1 x 6LR61

block

battery

1 x 6LR61

block

battery

Display

LCD

LCD

LCD

LCD

LCD

(514)

Digital current clamp multimeter

IP 30

5585 0101

5585 0102

5585 0501

5585

CM 1-1

Supplied with compact protective bag and battery.

0101

5585

CM 1-2

Supplied with compact protective bag, battery and dual-insulated safety

measurement lines.

0102

5585

CM 2

Precise due to true RMS measurement procedure TRUE RMS. Tested and

approved according to IEC/EN 61010-1 (DIN VDE 0411-1).

Ideal for measuring small currents. Supplied with compact protective bag, double

insulated safety measurement cables and batteries.

0200

5585

CM 5-1

Automatic selection of correct measuring function, incorrect measurements

as a result of choosing the wrong measuring range prevented, quick reaction times

thanks to 5 samples per second. The voltage measurement takes place with low

input impedance (LoZ) for the suppression of capacitive/inductive interspersed

voltages. For continuity and diode testing. Supplied with compact protective bag,

double insulated safety measurement cables and battery.

0501

5585

CM 7

Ideal for measuring current up to 1000 A (alternating and direct current).

Supplied with compact protective bag, dual-insulated safety measurement lines and

batteries.

0700

CAT

IV

CAT

III

CAT

III

Design:

Housing made of impact-resistant, unbreakable plastic, with automatic shutdown

function. Automatic range selection, resolution of 1 uA at 6 mA measuring range. Precise due

to true RMS measurement procedure TRUE RMS. Optimally shielded from foreign fields.

Supplied with compact protective bag and batteries.

Application:

For locating current leakages and measuring leakage and residual currents in

electrical installations (VDE 0100) and devices (VDE 0701/0702, DGUV Rule 3, Industrial

Safety Ord.). Measurement during normal operation of the plant/unit, ideal for preventive

maintenance and troubleshooting, reliable and easy to locate insulation faults. Switchable

low-pass filter (50–60 Hz).

Order No.

0900

Model

CM 9

5585

393.00

Alternating current

1 µA–100 A

Measured data storage

HOLD, PEAK

Measuring procedure

TRUE RMS

Pliers opening

40 mm

Measurement category

CAT III 300 V

Protection type

IP 30

Batteries

2 x micro AAA/LR03

Display

LCD

(514)

Current leakage meter

IP 30 CAT

III

5585 0200

CAT

III

5585 0700

CAT

IV

Test and measuring devices

948