City of Morgan Hill
Sanitary Sewer Flow Monitoring and Inflow/Infiltration Study
12-0248 AEG CofMorganHill FM Rpt.docx
TOC - vi
Term
Definition
Pipe Length: The RDI flow rate is divided by the length of pipe (IDM) in the
upstream basin. The result is expressed in gallons per day (gpd) per IDM
(gpd/IDM).
Basin Area: The RDI flow rate is divided by the geographic area of the
upstream basin. The result is expressed in gpd per acre.
ADWF: The RDI flow rate is divided by the average dry weather flow
(ADWF). This is a ratio and is expressed without units.
Normalization,
total I/I
The estimated totalized I/I in gallons attributable to a particular storm event is
used to identify basins with high total I/I. Because this is a totalized value rather
than a rate and can be attributable solely to an individual storm event, the
volume of the storm event is also taken into consideration. This allows for a
comparison not only between basins but also between storm events:
Pipe Length: Total gallons of I/I is divided by the length of pipe (IDM) in the
upstream basin and the rainfall total (inches) of the storm event. The result
is expressed in gallons per IDM per inch of rain.
Basin Area (R-Value): Total gallons of I/I is divided by total gallons of
rainfall water that fell within the acreage of the basin area. This is a ratio
and expressed as a percentage. R-value is described as “the percentage
of rainfall that enters the collection system.” Systems with R-values less
than 5%
1are often considered to be performing well.
ADWF: Total gallons of I/I is divided by the ADWF and the rainfall total of
the storm event. The result is expressed in million gallons per mgd of
ADWF per inch of rain.
Peaking factor
Ratio of peak measured flow to average dry weather flow. This ratio expresses
the degree of fluctuation in flow rate over the monitoring period and is used in
capacity analysis.
Surcharge
When the flow level is higher than the crown of the pipe, then the pipeline is said
to be in a
surcharged
condition. The pipeline is surcharged when the
d
/
D
ratio
is greater than 1.0.
Synthetic
hydrograph
A set of algorithms developed to approximate the actual I/I hydrograph. The
synthetic hydrograph is developed strictly using rainfall data and response
parameters representing response time, recession coefficient and soil saturation.
Weekend/weekday
ratio
The ratio of weekend ADWFs to weekday ADWFs. In residential areas, this ratio
is typically slightly higher than 1.0. In business districts, depending on type of
service, this ratio can be significantly less than 1.0.
1
Keefe, P.N. “Test Basins for I/I Reduction and SSO Elimination.” 1998 WEF Wet Weather Specialty Conference, Cleveland.