3M Petrifilm RYM Collaborative Study

June 2014

OMA-2014-June-XXX

ATCC 201382), manually mixed and held at -20 to -30°C for a

minimum of 2 weeks.

4.1.3.2.

Raw almonds

will be inoculated with a lyophilized culture

(

Aspergillus aculeatus

ATCC 56925) and stabilized for a minimum

of 2 weeks at room temperature (21-23°C).

4.2.

Shipment of Test portions

4.2.1. A total of 16 test portions (2 test portions x 4 levels x 2 methods) of each

matrix will be sent to each laboratory.

4.2.2. Test portions will be shipped in leak-proof, insulated containers with ice

packs to maintain the appropriate temperature range.

4.2.3. Packages will be sent via overnight courier.

4.3.

Test Portion Analysis

4.3.1. The laboratories will follow the appropriate test portion preparation

protocol according to the method for each food.

5.

3M Petrifilm RYM Count Plate

5.1.

Applicability

For the enumeration of yeast and mold from yogurt, sour cream, raw almonds,

sliced apples, frozen bread dough, ready-made pie, sandwiches, dehydrated soup,

fermented salami and frozen ground beef patties (80% lean/20% fat).

Caution

:

3M Petrifilm RYM Plates do not differentiate any one yeast or mold strain from

another. 3M has not documented 3M Petrifilm RYM Plates for use in industries

other than food and beverage. For example, 3M has not documented 3M Petrifilm

RYM Plates for testing water, pharmaceuticals or cosmetics. 3M Petrifilm RYM

Plates have not been tested with all possible food products, food processes, testing

protocols or with all possible strains of yeast and mold. Do not use 3M Petrifilm

RYM Plates in the diagnosis of conditions in humans or animals. The user must

train its personnel in proper testing techniques. After use, 3M Petrifilm RYM

Plates may contain microorganisms that may be a potential biohazard. Follow

current industry standards for disposal.

For information on potential biohazards,

reference Biosafety in Microbiological and Biomedial Laboratories, 5th edition,

Section VIII-B: Fungal Agents.

5.2.

Test Kit -

3M™

Petrifilm™ Rapid Yeast and Mold Count Plate

7

DRAFT DOCUMENT

AOAC Research Institute

Expert Review Panel Use Only

OMAMAN-16A/ Collaborative Study Protocol

ERP Use Only - December 2014