5

AOAC Official Method 2016.xxx

1

Listeria monocytogenes

in SelectFoods and Environmental Surfaces

2

3M

Molecular Detection Assay(MDA) 2-

Listeria monocytogenes

Method

3

First Action 2016

4

5

(Applicable to detection of

Listeria monocytogenes

hot dogs (25g & 125g), salmon (25g), deli

6

turkey (25g & 125g), cottage cheese (25g), chocolate milk (25 mL), vanilla ice cream (25g),

7

queso fresco (25g), romaine lettuce (25g), melon (whole), raw chicken leg pieces (25g); raw

8

chicken breast fillet (25g), concrete (3M™ Hydrated Sponge Stick with Dey-Engley [D/E] , 225

9

mL & 100 mL), stainless steel (3M Hydrated Sponge Stick with D/E, 225 mL), and plastic

10

(3M™ Enviroswab with Letheen, 10 mL) environmental samples.

11

12

See Tables

2016.1A

and

2016.1B

for a summary of results of the inter-laboratory study.

13

See Tables

2016.2A

and

2016.2B

for detailed results of the inter-laboratory study

14

15

A.

Principle

16

17

The 3M

Molecular Detection Assay (MDA) 2 -

Listeria monocytogenes

method is used with

18

the 3M

Molecular Detection System (MDS) for the rapid and specific detection of

Listeria

19

monocytogenes

in enriched food and food process environmental samples. The 3M MDA2 -

20

Listeria monocytogenes

uses loop-mediated isothermal amplification of unique DNA target

21

sequences with high specificity and sensitivity, combined with bioluminescence to detect the

22

amplification. Presumptive positive results are reported in real-time while negative results are

23

displayed after the assay is completed. Samples arepre-enriched in Demi Fraser with ferric

24

ammonium citrate broth.

25

26

B.

Apparatus and Reagents

27

Items (b)-(g) are available as the 3M

Molecular Detection Assay (MDA) 2 -

Listeria

28

monocytogenes

kit from 3M Food Safety (St. Paul, MN 55144-1000, USA).

29

(a)

3M Molecular Detection System

(MDS100) – Available from 3M Food Safety (St.

30

Paul, MN 55144-1000, USA).

31

(b)

3M Molecular Detection Assay 2 – Listeria monocytogenes reagent tubes-

12 strips of

32

8 tubes. Available from 3M Food Safety (St. Paul, MN 55144-1000, USA).

33

(c)

Lysis Solution (LS) tubes –

12 strips of 8 tubes.

34

(d)

Extra caps

– 12 strips of 8 caps

35

(e)

Reagent Control –

8 reagent tubes

36

(f)

Quick Start Guide

37

(g)

3M

Molecular Detection Speed Loader Tray -

Available from 3M Food Safety

38

(St. Paul, MN 55144-1000, USA).

39

(h)

3M

Molecular Detection Chill Block Insert

- Available from 3M

Food Safety (St.

40

Paul, MN 55144-1000, USA).

41

(i)

3M

Molecular Detection Heat Block Insert

- Available from 3M Food Safety

42

(St. Paul, MN 55144-1000, USA).

43

(j)

3M

Molecular Detection Cap/Decap Tool for Reagent tubes

- Available from 3M

44

Food Safety (St. Paul, MN 55144-1000, USA).

45

(k)

3M

Molecular Detection Cap/Decap Tool for Lysis tubes

– Available from 3M

46

Food Safety (St. Paul, MN 55144-1000, USA).

47

(l)

Empty Lysis Tube Rack

- Available from 3M Food Safety (St. Paul, MN 55144-1000,

48

USA).

49

AOAC Research Institute

Expert Review Panel Use Only

OMAMAN-30 A/ Collaborative Study Manuscript