IMRT for Prostate Cancer

DOSE REQUIREMENTS

PTV 74

99% of the volume to be covered by 95-105% of

prescribed dose (70.3 – 77.7Gy)

Median dose = 74Gy +/- 0.5Gy

Minimum dose to 99% volume = ≥ 95% (70.3Gy)

Maximum dose to 1% volume = <105% (77.7Gy)

PTV71

99% of the volume to be covered by 95% of 71Gy

(67.45Gy)

Median dose = 71Gy +/ - 1Gy