OMB Meeting Book_9-11-14 - page 84

COMMENT PARAMETERS 
USER COMMENTS 
AOAC OMA 
2012.15 
Method Name/Manuscript Title 
Total Iodine in Infant Formula and Adult Nutritionals by ICP MS 
Manuscript Reference 
In your experience using the method, does the 
method perform according to the method’s 
applicability as written? 
Sample preparation is by 5% or 50% KOH extraction and analysis by 
ICP‐MS for the range of 4 to 1500µg/100g. For 5%KOH extraction 
method, 5g slurry made up to 50mL (Total D.F = 80times). After 
extraction the solution so turbid, changed the color to brown and 
there is no clear solution obtained after refrigerated centrifugation or 
by filtering with 0.22µ filter. Further dilution of 10times more results 
final D.F to 800times. Method shows poor recovery for infant 
formula. 
In your experience with the method, is there 
any safety concerns identified while using or 
regarding use of the method? 
‐ 
Do you have any information that supports 
regarding the reproducibility of the method as 
written:  If so, please specify and submit 
information? 
‐ 
Please attach any documentation to support 
your feedback, if available.   
Based on your experience with the method, 
are there any recommended changes to the 
AOAC First Action Method as written? 
Extraction Method needs improvement. A different extraction proces 
is recommended with the use of different reagents. 