AOAC Official Method 2016.xxx

1

Listeria

speciesin SelectFoods and Environmental Surfaces

2

3M

Molecular Detection Assay(MDA) 2-

Listeria

Method

3

First Action 2016

4

5

(Applicable to detection of

Listeria

speciesin hot dogs (25g & 125g), salmon (25g), deli turkey

6

(25g & 125g), cottage cheese (25g), vanilla ice cream (25g), queso fresco (25g), spinach (25g),

7

melon (whole), raw chicken leg pieces (25g), raw chicken fillet (25g); concrete (3M™ Hydrated

8

Sponge Stick with D/E, 225 mL & 100 mL), stainless steel (3M™ Hydrated Sponge Stick with

9

D/E, 225 mL), and plastic (3M™ Enviroswab with Letheen, 10 mL) environmental samples.

10

11

See Tables

2016.1A

and

2016.1B

for a summary of results of the inter-laboratory study.

12

See Tables

2016.2A

and

2016.2B

for detailed results of the inter-laboratory study

13

14

A.

Principle

15

16

The 3M

Molecular Detection Assay (MDA) 2 -

Listeria

method is used with the 3M

17

Molecular Detection System (MDS) for the rapid and specific detection of

Listeria

in enriched

18

food and food process environmental samples. The 3M MDA2 -

Listeria

uses loop-mediated

19

isothermal amplification of unique DNA target sequences with high specificity and sensitivity,

20

combined with bioluminescence to detect the amplification. Presumptive positive results are

21

reported in real-time while negative results are displayed after the assay is completed. Samples

22

arepre-enriched in Demi Fraser broth with ferric ammonium citrate (FAC).

23

24

B.

Apparatus and Reagents

25

Items (b)-(g) are available as the 3M

Molecular Detection Assay (MDA) 2 -

Listeria

kit

26

from 3M Food Safety (St. Paul, MN 55144-1000, USA).

27

(a)

3M Molecular Detection System

(MDS100) – Available from 3M Food Safety (St.

28

Paul, MN 55144-1000, USA).

29

(b)

3M Molecular Detection Assay 2 – Listeria reagent tubes-

12 strips of 8 tubes.

30

Available from 3M Food Safety (St. Paul, MN 55144-1000, USA).

31

(c)

Lysis Solution (LS) tubes –

12 strips of 8 tubes.

32

(d)

Extra caps

– 12 strips of 8 caps

33

(e)

Reagent Control –

8 reagent tubes

34

(f)

Quick Start Guide

35

(g)

3M

Molecular Detection Speed Loader Tray -

Available from 3M Food Safety

36

(St. Paul, MN 55144-1000, USA).

37

(h)

3M

Molecular Detection Chill Block Insert

- Available from 3M

Food Safety (St.

38

Paul, MN 55144-1000, USA).

39

(i)

3M

Molecular Detection Heat Block Insert

- Available from 3M Food Safety

40

(St. Paul, MN 55144-1000, USA).

41

(j)

3M

Molecular Detection Cap/Decap Tool for Reagent tubes

- Available from 3M

42

Food Safety (St. Paul, MN 55144-1000, USA).

43

(k)

3M

Molecular Detection Cap/Decap Tool for Lysis tubes

– Available from 3M

44

Food Safety (St. Paul, MN 55144-1000, USA).

45

(l)

Empty Lysis Tube Rack

- Available from 3M Food Safety (St. Paul, MN 55144-1000,

46

USA).

47

(m)

Empty Reagent Tube Rack

- Available from 3M Food Safety (St. Paul, MN 55144-

48

1000, USA).

49

AOAC Research Institute

Expert Review Panel Use Only

OMAMAN-29 A/ Collaboartive Study Manuscript

OMA ERP June 2016

ERP Use Only