Table of Contents Table of Contents
Previous Page  229 / 453 Next Page
Information
Show Menu
Previous Page 229 / 453 Next Page
Page Background

17

Raw Ground Beef –

mericon

E. coli

O157

Screen Plus with Automated Preparation

1

For the low inoculum level, 69 out of 144 test portions (POD

CP

of 0.48) were reported as

2

presumptive positive by the

mericon

E. coliO157Screen Plus with 65 out of 144 test portions

3

(POD

CC

& POD

R

of 0.45) confirming positive. For samples that produced presumptive positive

4

results on the

mericon

E. coli O157Screen Plus, 65 out of 144 samples confirmed positive

5

(POD

C

of 0.45). A dLPOD

C

value of 0.00 with 95% confidence interval of (-0.12, 0.12) was

6

obtained between the candidate and reference method, indicating no statistically significant

7

difference between the two methods. A dLPOD

CP

value of 0.03 with 95% confidence intervals of

8

(-0.09, 0.15) was obtained between presumptive and confirmed results indicating no statistically

9

significant difference between the presumptive and confirmed results.

10

11

For the high inoculum level, 144 out of 144 test portions (POD

CP

of 1.00) were reported as

12

presumptive positive by the

mericon

E. coliO157Screen Plus with 144 out of 144 test portions

13

(POD

CC

& POD

R

of 1.00) confirming positive. For samples that produced presumptive positive

14

results on the

mericon

E. coli O157Screen Plus, 144 out of 144 samples confirmed positive

15

(POD

C

of 1.00). A dLPOD

C

value of 0.00 with 95% confidence interval of (-0.03, 0.03) was

16

obtained between the candidate and reference method, indicating no statistically significant

17

difference between the two methods. A dLPOD

CP

value of 0.00 with 95% confidence intervals of

18

(-0.03, 0.03) was obtained between presumptive and confirmed results indicating no statistically

19

significant difference between the presumptive and confirmed results.

20

21

For the un-inoculated controls, 2 out of 144 samples (POD

CP

of 0.01) produced a presumptive

22

positive result by the

mericon

E. coliO157Screen Plus with 0 out of 144 test portions (POD

CC

&

23

POD

R

of 0.00) confirming positive. For samples that produced presumptive positive results on

24

the

mericon

E. coliO157Screen Plus, 0 out of 144 samples confirmed positive (POD

C

of 0.00).

25

A dLPOD

C

value of 0.00 with 95% confidence interval of (-0.03, 0.03) was obtained between the

26

candidate and reference method, indicating no statistically significant difference between the two

27

methods. A dLPOD

CP

value of 0.01 with 95% confidence intervals of (-0.01, 0.05) was obtained

28

between presumptive and confirmed results indicating no statistically significant difference

29

between the presumptive and confirmed results.

30

31

Detailed results of the POD statistical analysis are presented in Table 2016.2Cand Figures 3A-

32

3B.

33

34

Raw Ground Beef –

mericon

E. coliSTEC O-Type with Automated Preparation

35

For the low inoculum level, 63 out of 144 test portions (POD

CP

of 0.44) were reported as

36

presumptive positive by the

mericon

E. coliSTEC O-Type with 65 out of 144 test portions

37

(POD

CC

& POD

R

of 0.45) confirming positive. For samples that produced presumptive positive

38

results on the

mericon

E. coliSTEC O-Type, 63 out of 144 samples confirmed positive (POD

C

of

39

0.44). A dLPOD

C

value of -0.01 with 95% confidence interval of (-0.13, 0.10) was obtained

40

between the candidate and reference method, indicating no statistically significant difference

41

between the two methods. A dLPOD

CP

value of -0.01 with 95% confidence intervals of (-0.13,

42

OMAMAN-36 A : Collaborative Study Manuscript

For ERP Use Only

January 2017

AOAC Research Institute