Reviewer Name:

Melissa Phillips

Email:

melissa.phillips@nist.gov

Organization:

NIST

Method Reviewed:

TUR‐02

Method Title:

Quantitation of Curcuminoids

Applicable SMPR

2016.003

Summary of Method:

An 80:20 methanol:water extraction followed by LC‐absorbance for determination of 

CUR, BDMC, and DMC in turmeric materials.  Optimization of some extraction 

parameters was discussed.

1.  Does the Applicability of the 

Method Support the Applicability 

of the SMPR?  If not, please explain 

what is missing.

Yes

2.  Does the analytical technique(s) 

used in the method meet the 

SMPR?  If not, please specify how it 

differs from what is stated in the 

SMPR.

Yes

3.  Are the definitions specified in 

the SMPR used and applied 

appropriatly in the method?  If no, 

please indicate how the terms are 

used.

Yes

4.  Does the method, as written, 

contain all appropriate precautions 

and warnings related to the 

method's regaents, components, 

instrumentation, or method steps 

that may be hazardous?  If no, 

please suggest wording or 

option(s).

No safety information is included.  Could potentially include a statement regarding 

flammability of solvents, acidity of mobile phase, as well as use of elevated column 

temperature, but this is not critical.

1.  Are the definitions specified in 

the SMPR used and applied 

appropriately in the supporting 

documentation (manuscripts, 

method studies, etc…)?  If not, 

please explain the differences and 

if the method is impacted by the 

difference.  

Yes

2.  Is there information 

demonstrating that the method 

meets the SMPR Method 

Performance Requirements using 

the Reference Materials stated in 

the SMPR?   If not,  then specify 

what is missing and how this 

impacts demonstration of 

performance of the method.  

Reference standards were acquired from a different vendor (Chromadex) than those 

listed in the SMPR; purity of standards should be evaluated and confirmed or 

corrected in‐house.

Matrix reference materials listed in SMPR were not used in this study (although they 

are not yet available from NIST).

General Information

I.  Summary

II.  Review of the Method Only

III.  Review of Information in Support of the Method