Table of Contents Table of Contents
Previous Page  219 / 1195 Next Page
Information
Show Menu
Previous Page 219 / 1195 Next Page
Page Background

AOAC INTERNATIONAL

MODIFICATION TO THE BAX® SYSTEM REAL-TIME PCR ASSAY FOR

1

SALMONELLA

(

PERFORMANCE TESTED METHOD

SM

#081201) IN

2

SELECTED FOODS: ADDITION OF EIGHT PCR CYCLES TO IMPROVE

3

SENSITIVITY

4

5

1. ABSTRACT

6

In August 2012, the AOAC Research Institute (AOAC-RI) certified the BAX® System Real-Time

7

PCR Assay for

Salmonella

as comparable to the USDA-FSIS, U.S. FDA and Health Canada reference

8

methods for detecting

Salmonella

in raw ground beef, chicken carcass rinses, cream cheese, bagged

9

lettuce, dry pet food and stainless steel environmental samples.

10

Since then, expanded use in real-world samples and additional research suggests that results for

11

low-level positive samples could be improved by slightly extending the processing time. Internal studies

12

showed that adding eight cycles to the PCR program for the real-time

Salmonella

assay minimizes the risk

13

of a false negative result for samples at or near the limit of detection, and slightly increases the method’s

14

sensitivity.

15

All components of the certified method remain unaltered, including PCR tablet chemistry,

16

temperature profile of the PCR and detection process, and all step-by-step instructions for sample

17

enrichment and preparation. Moreover, because the real-time

Salmonella

assay already incorporates a

18

“hot-start” polymerase and Scorpion™ probe technology, the risk of non-specific product formation, or

19

other potentially negative effects from slightly extended PCR, is minimal.

20

Several studies were conducted to compare the performance of the updated BAX® System

21

method to both the current certified method and the appropriate reference culture methods on a range of

22

artificially contaminated matrices. In addition, inclusivity and exclusivity studies were performed to

23

demonstrate no significant change in the sensitivity and specificity of the assay.