Table of Contents Table of Contents
Previous Page  250 / 1195 Next Page
Information
Show Menu
Previous Page 250 / 1195 Next Page
Page Background

AOAC INTERNATIONAL

Agriculture Food Safety and Inspection Service (USDA-FSIS)

[4]. These culture methods each

91

require at least three days for a negative result and often many more days if there are potential

92

or actual

Salmonella

present in an enriched matrix. Rapid methods for screening

Salmonella

93

have been developed, but these generally require two days of enrichment. By contrast, the

94

BAX® System detects the pathogen approximately 1.5 hours after a 12-24 hour enrichment,

95

and the DNA-based results are both reliable and reproducible, leading to quicker release of

96

cleared product.

97

98

9. TEST KIT INFORMATION

99

100

Test kit name

– BAX

®

System Real-Time PCR Assay for

Salmonella

.

101

Test kit catalog number – D14306040

102

Ordering information –

103

DuPont Qualicon, Experimental Station, Bldg. 400, P.O. Box 80400, Rt. 141 & Henry Clay

104

Road, Wilmington, DE 19880-0400, USA, Phone 800-863-6842 or 302-695-5300, Fax 302-

105

695-5301, Internet

www.qualicon.com

106

DuPont Qualicon

Europe,

Ltd Wedgwood Way, Stevenage Herts SG1 4QN, UK

107

DuPont Qualicon,

Asia/Pacific DuPont Company (Singapore) Pte, Ltd. 1 Harbour Front Place

108

#11-01, Harbour Front Tower One, Singapore 098633

109

110

Test kit components –

111

112

PCR tubes with tablets (twelve 8-tube strips, each tube containing 1 PCR tablet)

113

Flat optical caps for PCR tubes (twelve 8-cap strips)

114

Lysis buffer (two 12-mL bottles)

115

Protease (one 400-µL vial)

116

117

118

119

120

121

Dupont BAX Salmonella PTM Report

PTM Certification No. 081201 (08/07/2012)

For Expert Review Panel Use Only

Do Not Distribute