= 0, CI: -0.28 to 0.28). There was no significant difference between the LPT method and
1
the reference method using unpaired Chi-square test (
X
2
= 0.40) or the POD (dPOD =
2
0.10, CI: -0.37 to 0.19). See Tables 5, 8, 9 in the Appendix
3
Vanilla ice cream
4
For the vanilla ice cream analysis there were 18 confirmed positives for the LPT method
5
and 15 confirmed positives for the AOAC reference method. All uninoculated samples
6
were negative with both methods. There were no false positives for the VIDAS method
7
(dPOD = 0, CI: -0.21 to 0.21). There was no significant difference between the LPT
8
method and the reference method using unpaired Chi-square test (
X
2
= 1.52) or the POD
9
(dPOD = 0.15, CI: -0.09 to 0.38). See Tables 6, 8, 9 in the Appendix.
10
Queso fresco – 25g
11
For the queso fresco (25g) analysis there were 9 confirmed positives for the LPT method
12
and 11 confirmed positives for the AOAC reference method. All uninoculated samples
13
were negative with both methods. There were no false positives for the VIDAS method
14
(dPOD = 0, CI: -0.28 to 0.28). There was no significant difference between the LPT
15
method and the reference method using unpaired Chi-square test (
X
2
= 0.39) or the POD
16
(dPOD = 0.10, CI: -0.37 to 0.19). See Tables 6, 8, 9 in the Appendix.
17
Queso fresco - 125g
18
For the queso fresco (125g) analysis there were 11 confirmed positives for the LPT
19
method and 11 confirmed positives for the AOAC reference method. All uninoculated
20
samples were negative with both methods. There were no false positives for the VIDAS
21
method (dPOD = 0, CI: -0.28 to 0.28). There was no significant difference between the
22
LPT method and the reference method using unpaired Chi-square test (
X
2
= 0) or the POD
23
(dPOD = 0, CI: -0.28 to 0.28). See Tables 6, 8, 9 in the Appendix.
24
Ceramic tile
25
For the ceramic analysis there were 6 confirmed positives for the LPT method and 3
26
confirmed positives for the USDA reference method. All uninoculated samples were
27
negative with both methods. There were no false positives for the VIDAS method (dPOD
28
= 0, CI: -0.27 to 0.27). There was no significant difference between the LPT method and
29
the reference method using unpaired Chi-square test (
X
2
= 1.26) or the POD (dPOD =
30
0.15, CI: -0.11 to 0.39. See Tables 7, 8, 9 in the Appendix.
31
Stainless steel
32
For the stainless steel analysis there were 10 confirmed positives for the LPT method and
33
1 confirmed positives for the USDA reference method. All uninoculated samples were
34
negative with both methods. There was one false positives for the VIDAS method (dPOD
35
= 0.45, CI: -0.24 to 0.33). There was a significant difference between the LPT method
36
and the reference method using unpaired Chi-square test (
X
2
= 11.61) and the POD
37
(dPOD = 0.45, CI: 0.18 to 0.65). See Tables 7, 8, 9 in the Appendix.
38
Plastic (polypropylene)
39
54