presumptive positives and 5 confirmed positives following the FDA/BAM

Chapter 4A reference method confirmation procedure. There were 5

confirmed positives following the reference method.

For the low inoculation level, a dPOD

C

value of -0.10 was obtained with a

95% confidence interval of (-0.37, 0.19), indicating no significant

difference between the candidate and reference methods. A dPOD

CP

value of 0.00 was obtained with a 95% confidence interval of (-0.28,

0.28), indicating no significant difference between the candidate

presumptive and confirmed results.

For the high inoculation level, a dPOD

C

value of 0.00 was obtained with a

95% confidence interval of (-0.43, 0.43), indicating no significant

difference between the candidate and reference methods. A dPOD

CP

value of 0.00 was obtained with a 95% confidence interval of (-0.43,

0.43), indicating no significant difference between the candidate

presumptive and confirmed results. Detailed results of the POD analyses

are presented in Tables 16 and 20 of the Appendix.

Raw Ground Beef (70% Lean)

For the low inoculation level of the

mericon

E. coliSTEC O-Type Pathogen

Detection Assay, there were 9 presumptive positives and 9 confirmed

positives following the USDA/FSIS-MLG 5.09 reference method

confirmation procedure. There were 9 observed positives for the

reference method. For the high inoculation level, there were 5

presumptive positives and 5 confirmed positives following the

USDA/FSIS-MLG 5.09 reference method confirmation procedure. There

were 5 confirmed positives following the reference method.

For the low inoculation level, a dPOD

C

value of 0.00 was obtained with a

95% confidence interval of (-0.28, 0.28), indicating no significant

difference between the candidate and reference methods. A dPOD

CP

value of 0.00 was obtained with a 95% confidence interval of (-0.28,

0.28), indicating no significant difference between the candidate

presumptive and confirmed results.

For the high inoculation level, a dPOD

C

value of 0.00 was obtained with a

95% confidence interval of (-0.43, 0.43), indicating no significant

difference between the candidate and reference methods. A dPOD

CP

value of 0.00 was obtained with a 95% confidence interval of (-0.43,

0.43), indicating no significant difference between the candidate

presumptive and confirmed results. Detailed results of the POD analyses

are presented in Tables 16 and 20 of the Appendix.

Raw Beef Trim

For the low inoculation level of the

mericon

E. coliSTEC O-Type Pathogen

Detection Assay, there were 13 presumptive positives and 13 confirmed

OMAMAN-36 E/ AOAC PTM Report

ERP Use Only

January 2017

AOAC Research Institute

Expert Review Panel Use Only