Table 7.9 Schedule of Improvements

Water System Master Plan

City of Morgan Hill

PRELIMINARY

Pipeline Improvements

New/Parallel

/Replace

Diam.

Length

(in)

(in)

(ft)

Pipeline Improvements

Boys Ranch Pressure Zone

BR-P1

Boys Ranch

ROW Cochrane Rd to Coyote Rd

-

New

10

1,600

BR-P2

Boys Ranch

Cochrane Rd Half Rd to approx 1,700' n/o Half Rd

-

New

10

1,700

BR-P3

Boys Ranch

Half Rd

Mission View Dr to Peet Rd

-

New

12

3,150

BR-P4

Boys Ranch Mission View Dr

Between Cochrane Rd and 2,100' nw/o

Cochrane Rd

-

Replace

10

450

BR-P5

Boys Ranch Mission View Dr Half Rd to 2,100' nw/o Half Rd

-

New

12

2,100

BR-P6

Boys Ranch

Half Rd

Serene Dr to Conduit Rd

-

New

12

1,650

Nob Hill Pressure Zone

NH-P1

Nob Hill

Hale Ave Extension Spring Ave to Main Ave

-

New

12

4,550

NH-P2

Nob Hill

Spring Ave Del Monte Ave to Monterey Rd

4

Replace

8

950

NH-P3

Nob Hill

San Pedro Ave Butterfield Blvd to Railroad Ave

10

Replace

16

550

NH-P4

Nob Hill

Railroad Ave San Pedro Ave to approx 600' n/o Mast St

10

Replace

16

350

NH-P5

Nob Hill

Railroad Ave Approx 600' n/o Mast St to Mast St

6

Replace

16

600

NH-P6

Nob Hill

San Pedro Ave Peppertree Dr to Hill Rd

-

New

10

3,200

NH-P7

Nob Hill

Hill Rd

San Pedro Ave to Tennant Ave

-

New

10

3,300

NH-P8

Nob Hill

Tennant Ave Hill Rd to Conduit Rd

-

New

10

4,850

NH-P9

Nob Hill

Monterey Rd John Wilson Way to Middle Ave

-

New

10

2,350

NH-P10

Nob Hill

ROW Monterey Rd to Olive Ave

-

New

10

2,700

Holiday Pressure Zones

HL-P1

Holiday 1

Dunne Ave Flaming Oak Ln to Proposed E Dunne Tank

-

New

16

550

HL-P2

Holiday 1

Dunne Ave Proposed E Dunne Tank to Flaming Oak Ln

-

New

12

550

HL-P3

Holiday Lake

Dunne Ave Proposed E Dunne Tank to Flaming Oak Ln

-

New

12

2,450

HL-P4

Holiday Lake

Oak Leaf Dr

Dunne Ave to 650' w/o Lori Dr

-

New

12

2,300

HL-P5

Holiday Lake

Lake View Dr

Oak Leaf Dr to Holiday Lake Tanks

8

Replace

12

2,850

Storage Reservoir Improvements

Proposed Storage Capacity

(MG)

BR-T1

Boys Ranch Demolish existing 0.55 MG Boys Ranch tank and replace with 1.20 MG tank

Replace

1.20

GA-T1

Glen Ayre

Demolish existing 0.10 MG Glen Ayre tank and replace with 0.25 MG tank

New

0.25

ED-T1

Nob Hill

Existing Edmundson tank site

New

0.90

Improv. No.

Existing

Diameter

Limits

Alignment

Pressure Zone